The IFC takeoff page now loads its 3D viewer when you open a model
The free IFC takeoff page sends 37 kB less on first load. Its 3D viewer, revision diff and STEP reader now load only when a model needs them.
-
A bridge deck 25 metres above its girders: reading a second IFC 4.3 bridge exporter
Three WSDOT PGSuper bridges now read in full. Their decks sat 25 m above the girders, and their vertical curves departed from the IFC text three ways.
-
A Revit wall split at a level was counted twice, and a Tekla plate stored its paint area
Two IFC stored-quantity faults traced to the file: a split wall's whole figure on one piece, and a plate's NetArea that is every face of its body.
-
The last three areas in doubt were a brick band's underside
Three ArchiCAD coping areas six to nineteen times their profile were the flat underside. Reading faces off a body built from signed pieces named them.
-
Coped steel beams in IFC: a paint area checked three ways, and where IfcOpenShell's cut goes wrong
The free IFC takeoff now measures coped steel members' paint area from their cut faces: 825 of 825 parts on 8 public models, checked three ways.
-
A bridge model's takeoff, a third faster with the same bytes: strings and pairs, not maths
Profiling the free IFC takeoff on a public IFC 4.3 bridge: the time went to string keys and small arrays, not geometry. 17.6 s to 11.5 s, same output.
-
Revit's gross wall area was one face with the windows taken out
Three wall areas an IFC takeoff could not explain match one wall face net of its openings to 1e-6. Five walls in two Revit models; 3 figures left in doubt.
-
A 1% steel volume error that was the section, not the boolean
Two notched steel angles read 1% heavy in an IFC takeoff. The cut was fine: the L section's toe radii were never drawn. Now within 0.02% of IfcOpenShell.
-
Steel paint area from an IFC model: a coating column, checked against section tables
The free IFC takeoff now gives a coating area for every steel part, matching published section tables; 797 of 825 parts on 8 public models.
-
A curved wall with square ends: the volume check that was missing a term
Why a stepped arc wall with square-cut ends failed the volume check on its faces, and the one exact term per plane that fixes it.
-
A curved wall's side area from its IFC facets: 897 m2 the bill was missing
A plane cut through a wall on an arc gives a chord. Measured on its facets, 45 such walls in public models carry 1,330 m2 of side area, not 434.
-
The curved wall that failed its volume check had a duct inside it
Two curved walls in a public IFC model were refused as leaning triangles. They hide a ventilation duct; measured right, they match their own axis to 0.02%.
-
Drawing rebar from an IFC swept disk: a tube that encloses exactly what it should
Bars in IFC are swept disks with no faces, so the takeoff's 3D view drew none. Now 788 of 788 bar elements are drawn, and boxes match IfcOpenShell.
-
A half-round wall has both ends on one plane, and that broke our curved-wall takeoff
Two 180-degree tunnel walls read 5.58 m2 too much outer face. The cause was not CSG cutters but geometry: both ends share one plane through the centre.
-
Rail cant in IFC 4.3: two readings of one sample, 100 times apart
The takeoff now reads rail cant. On buildingSMART's sample it matches the worked text to 1e-17 m. IfcOpenShell's elevation is 100 times the text's.
-
Rebar hooks in an IFC bar schedule: which end, how long, and whose number
Reading hooks from Tekla and Revit bars: 45 of 45 named hook angles match the drawn bend once ends are matched either way round.
-
When the reference is wrong: counting a geometry kernel's inside-out faces
Checking every IfcOpenShell brep mesh for faces turned the wrong way cut the unexplained volume disagreements on two public IFC models from 15 to 5.
-
A safety guard that blocked nothing: testing a curved-wall check on negative geometry
A guard kept stepped curved walls with negative terms off a volume check. Tested on built walls it held to 1e-14; on 28 public models it moved nothing.
-
An IFC change report that missed every room, scored against 20 Archicad edits
On 20 Archicad 27 edits with a written list of changes, the change report found every door and wall but 0 of 44 new rooms. Now it finds all 87 additions.
-
Two slabs were 43% of a model's concrete: stored IFC volumes in doubt
Two sloped slabs in a public Revit IFC stored 6,421 m3 against 6.5 m3 of body. Our free takeoff now shows every figure in doubt and lets you price either.
-
Two tools, two different cones: the 0.12% an IFC exporter's B-spline hid
One IFC fitting is two solids: polynomial faces 0.042 mm inside circular edges. Our takeoff reads the faces, IfcOpenShell the circles. Both are right.
-
A bar bending schedule from the bars themselves, checked against Tekla's own
Our free IFC takeoff now reads each rebar's path into a schedule by bar mark. On real Tekla files the counts and weights match Tekla's own.
-
A beam that stores a quarter too much steel, and three guides to IFC quantities
Writing how-to guides for the free IFC takeoff turned up a missed check: a member's stored volume against its own length times section. Now caught.
-
A bridge that would not open: reading IFC 4.3 alignments for a bill of quantities
A public IFC4X3 bridge stopped our takeoff on its first pile. Now all 6,448 parts read, placed within 1e-7 m of IfcOpenShell and measured to 0.003%.
-
ArchiCAD doors with side lights count the leaf's glass, not the side lights'
Four ArchiCAD doors with side lights store a volume that keeps the leaf's glass and drops the side lights'. Grouping panes by plane names it, 4 of 4.
-
Rebar and grid-placed columns: what buildingSMART's own IFC samples showed our takeoff could not read
On buildingSMART's 46 IFC4.3 sample models the takeoff read 79 of 141 elements. It now reads 140, including every rebar with a length and a mass.
-
Comparing IFC revisions: when 13 added windows are really 2 swaps and 9 re-placements
A designer who deletes a window and places another in the same opening gives it a new GlobalId and a new Revit id. The free change report now pairs them.
-
Why an IFC model's stored areas disagree with its geometry: holes, faces and curved walls
On eight public BIM models, 117 stored areas had no known reason to differ from the geometry. 103 now have one, each exact to the digit.
-
603 mullions that measured their whole facade: member lengths from IFC geometry
Half of 10,035 beams and columns in 30 public IFC models store no length. The body gives it, and caught 5,480 m of mullion that was really 795 m.
-
When the reference kernel turns a face inside out: five curved IFC solids traced
A domed basin bottom now reads in our IFC takeoff, and five volume gaps against IfcOpenShell turned out to be its own faces facing inward.
-
A roof slab that stored 93 times its concrete: two IFC export habits named
On public IFC models, 20 Revit slabs stored litres divided by 10.7639 as m3. Our free takeoff now names that and 105 ArchiCAD walls exported net.
-
ArchiCAD's stored window volume leaves out the glass
On a public ArchiCAD IFC, windows store Net Volume as the frame and sash without the panes, a quarter short. The takeoff now names it and sums the panes.
-
Knee walls under a roof are not exterior walls: teaching an IFC takeoff to see roofs
Our free IFC takeoff now lets sloped roofs stop its envelope rays. On one Dutch model, flag agreement went from 815 to 853 of 922 walls.
-
Tekla's stored steel weights leave out the root fillets
On a public Tekla IFC, stored NetVolume and NetWeight come from the section without its fillets: an IPE240 5% light. The takeoff now names and corrects it.
-
Three in four overlapping pairs were empty: a faster IFC takeoff, same bytes
Our in-browser IFC takeoff ran 17.5% faster over 28 public models, with byte-identical results, after we stopped clipping polyhedra that could not meet.
-
A mullion whose cross-section is half its surface, and footings we cut on a slant
58 Revit mullions store half their surface as CrossSectionArea, and mitred footings were cut on a slant. Unexplained IFC cross-sections fell from 77 to 2.
-
Why ArchiCAD's wall areas come in under the geometry, and mullions that carry a whole curtain wall
Two causes found in public IFC models: ArchiCAD takes T-joined walls off a wall's side area, and Revit mullions store their curtain wall's area on every piece.
-
Cutting an IFC mesh with a plane: 4,251 more stored areas checked
Our IFC takeoff now cuts triangle meshes by a plane. On 8 public models, 2,915 of 4,251 newly checked stored areas agree; most misses are small pieces.
-
Every window flagged interior: sorting IFC models into Uniformat II
Our IFC takeoff now groups a bill of quantities by Uniformat II element. On 17 public models the rules match 482 of 588 author-set codes.
-
Exterior wall or partition? Asking the geometry when the IFC flag lies
Our IFC takeoff now sorts walls into exterior walls or partitions by casting rays from each face. On 17 public models the IsExternal flag was often wrong.
-
IFC mesh faces written backwards, and what the stored areas that miss really are
Turning reversed mesh faces fixed 58 Revit volumes, and four rules named 1,141 of the 1,499 stored IFC areas our takeoff could not explain.
-
Is that beam holding up a floor or the roof? Reading it from IFC geometry
Our free IFC takeoff now sorts beams and columns into floor, roof or foundation structure by what sits on them: 1,168 placed on 17 public models.
-
Pipe bends and NURBS: reading curved IFC breps in a browser takeoff
Our free IFC takeoff now measures breps on surfaces of revolution and NURBS. 24 of 27 read; twice, IfcOpenShell's figure failed a check by formula.
-
Most IFC advanced breps are not NURBS: reading 767 of 775 exactly
99% of one model's IfcAdvancedBrep bodies were planes and cylinders. Reading them took a chord rule, a face-with-a-hole fix and signed tetrahedra.
-
A Revit IFC export whose inch is 3.6576 metres
A 2014 Revit IFC export declares its inch as 144 inches, so every volume reads 3 million times too big. How the free IFC takeoff now spots and repairs it.
-
Slab on grade, gutters and balcony rails: three more fixes to an IFC Uniformat estimate
164 elements in 17 public IFC models were filed in the wrong Uniformat element or none. How our free takeoff now finds slabs on grade, gutters and outer rails.
-
Slabs that aren't floors: roofs, carpets and sun fins in IFC models
Of 600 IFC slabs typed FLOOR in 17 public models, 330 were finishes, sun fins or roofs. How our free takeoff now tells them apart for a Uniformat estimate.
-
Leaving small voids in: a measurement rule for an IFC bill of quantities
Our free IFC takeoff can now leave small openings in, as measurement rules do. 2,252 openings cut on 12 public models; 1,099 of 1,136 matched width x height.
-
One void threshold for every element moved slab areas on 4 of 11 models
Our free IFC takeoff now sets small-void thresholds per work section. One pair for everything added up to 7.2 m2 of slab area that a volume rule leaves alone.
-
What changed between two IFC revisions? GlobalIds lie 19% of the time
Our free IFC takeoff now compares two model revisions. On five real Revit exports of one house, 190 of 1,011 GlobalId-only adds and removes were one element.