Tekla's stored steel weights leave out the root fillets

On a public Tekla IFC, stored NetVolume and NetWeight come from the section without its fillets: an IPE240 5% light. The takeoff now names and corrects it.

An IPE240 has a cross-section of 39.1 cm2. That figure includes the four root fillets, the curved corners where the web meets the flanges. Leave them out and you get 37.2 cm2, about 5% less steel.

On Tekla's public sample model in the web-ifc test set (ISSUE_021_Mini Project.ifc), the stored NetVolume and NetWeight of every rolled section leave them out. An IPE240 beam 8.46 m long stores 0.03143 m3 and 251.5 kg. The geometry in the same file, an IfcIShapeProfileDef with a 15 mm root radius, has 0.03307 m3. The same model stores CrossSectionArea = 0.003911 m2 on another IPE240 part, which is the catalogue area with the fillets. So the file disagrees with itself, and the weight a scheduler or estimator would read is the low one.

It is not only I sections. On that model:

SectionPartsStored under the geometry byWhy
IPE240, IPE300, HEA18083.6 to 4.9%no root fillets
angles (L65/130/8, L100/100/10, L80/80/8)682.0 to 2.5%no root fillet
round tube 60 x 1222.6%drawn as 16-sided polygons
round tube 20 x 12010.0%drawn as 8-sided polygons
square tube 60 x 323.5% overcorner radii left out

Each ratio is exact: draw the profile again without its radii, or with its circles as 8- or 16-gons, and the area ratio matches the stored figure to four decimals on every unclipped part, at any length.

What the takeoff does with it

The IFC quantity takeoff already compared every stored volume with the volume it computes from the geometry. These 142 stored figures (120 NetVolumes, 22 GrossVolumes) were "unexplained". Now, for any body swept from one parametric profile, it draws the simplified sections too. When the stored figure matches one of them to 0.5%, it names the cause (simplified-section). The bill of quantities then uses the geometry, and the stored weight is scaled up by the same ratio. A drawn (arbitrary) profile never gets this explanation, and a stored volume 10% off on the same angle still shows as unexplained.

Two more causes from the same pass

  • One stair's total on every piece. On a Revit school model (ISSUE_068_ARK_NUS_skolebygg.ifc), all 14 stringers of one stair store NetVolume 1.34012 m3. That is the stair's flights, landings and stringers added up, to five decimals (railings excluded). A stringer's own volume is 0.0004 to 0.012 m3. Summed as stored, the model's member volume was 18.16 m3; with each piece's own geometry it is 11.52 m3.
  • A stored zero. Six ArchiCAD skylights store NetVolume 0. The bill of quantities now counts their 0.18 m3 each instead of nothing.

Across the 13 public models we test on, unexplained NetVolumes fell from 233 to 83. The 81 that matter most are ArchiCAD windows and doors whose stored "Net Volume" changes from one placement to the next on identical bodies. Those are the next thing to read. The method and every number are in the repository: ventures/ifc-quantity-takeoff/eval/netvolume-causes-2026-11-21.md.

The effect on this particular model is small (58 kg on 829 t), because the affected parts are small angles, eyes and pins. On a frame built from rolled sections, the same habit puts every member 2 to 5% under.

Estimates from public sample files, not engineering advice. Check quantities that matter against the drawings and the supplier's section tables.

All writing · More in Tools and projects · More on IFC Quantity Takeoff · All tools and research