A building model's net wall area has every opening taken out, down to the smallest pipe sleeve. A quantity surveyor's bill doesn't work that way. Most written methods of measurement leave small voids in: a hole under some size isn't deducted from the plaster or the blockwork. A takeoff that sums the model's net figures therefore disagrees with the measured bill on every wall with a duct sleeve in it.
The free IFC Quantity Takeoff now has an "Openings" control under the bill of quantities. You can deduct every opening (as modelled), leave in voids up to 0.50 m² of area and 0.05 m³ of volume, or set your own thresholds. On the command line it's node cli.mjs model.ifc --voids-up-to 0.5,0.05. Thresholds vary by standard, edition and work section, so the tool doesn't claim any standard's rules. You type the numbers your contract's method gives.
Measuring each opening on its own
To leave an opening in, you need to know what that opening alone takes out. The takeoff already subtracted every opening from each element's body exactly. Now it also subtracts each one separately, and records the volume it removes and the area it removes from the section the bill measures (a wall's middle plane, a slab's plan). A net figure gets the small openings added back. A gross figure, one the geometry check confirms still has its openings in, gets only the large ones taken out. A figure whose basis is unknown is used as it stands, and the row says why.
Adding an opening back is exact only if the openings don't overlap. So the rule checks that the separate deductions sum to what all the openings take out together. In 993 of 1,003 elements they did. The other 10 were all in one Norwegian school model, where overlapping openings meant the rule couldn't tell what to add back. Those elements stay as modelled and get counted on their bill line.
Checked against what the exporters stored
Some exporters store each opening's own width and height. For openings through walls, we compared the area cut for each opening with width × height: 1,099 of 1,136 agree within 2%, across 12 public models from Revit, ArchiCAD and others. Two of the misses are round windows in AC20-FZK-Haus. The cut gives 0.785 m² against a 1 × 1 m box. That's π/4, so the cut is the right figure. 31 more are openings in that school model that barely touch the wall that names them as host, 0.01 to 0.06 m² cut against about 3 m². Those are still open.
How much it moves a bill
Not much at the building level, but it falls on the lines priced per square metre. Of 2,252 openings, 216 (9.6%) are at or under 0.50 m². At that threshold the wall and slab area moves by less than a quarter of a percent per model (+10.6 m² on the dental clinic, +7.2 m² on the HHS office, almost all of it in slabs). At 1.00 m² it moves up to 1.41% on OpeningDesign's Schultz Residence, where the walls alone go up 2.35%. The method and every number are in eval/measure-rules-2026-11-20.md.
One older claim turned out to be wrong. The README said overlapping openings in one element were subtracted twice. A test with two overlapping openings in a 10 m wall gives exactly the 24 m³ the union leaves, so they're taken out once, and the README now says so.
Next: different thresholds per class or work section, and mapping classification codes to Uniformat and MasterFormat elements, the other half of a method-of-measurement layer.