When the export has no quantities: measuring Qto_ values from the model's own geometry

Our free IDS checker can now write missing Qto_ volumes and areas measured from each element's body. On real exports 95% match stored values within 2%.

A client's IDS asks every wall for Qto_WallBaseQuantities.NetSideArea and NetVolume. The architect exports from Revit with quantities turned off, and the check fails on every wall. The fix usually means a round trip: change the export settings, export again, check again.

The free IDS checker and editor could already write missing values into a copy of the .ifc: values the IDS fixes, values a person types into a table, and quantities the element holds under another set name (IFC2X3 exports keep them in BaseQuantities). A Revit export with no quantity sets got nothing from that. Every Qto_ request went to the table for someone to type in.

Today it can measure them. Tick Measure missing Qto_ volumes and areas (or add --from-geometry on the command line), and quantities no set holds are measured from each element's body by the engine behind our IFC quantity takeoff. That covers gross and net volume for anything with a body, wall side and footprint areas and width, slab and roof areas, and member cross-sections. Lengths and heights are left out on purpose. A Qto_ Length is a centre-line or nominal figure, and the body alone does not say which.

How close are the measured values?

Two of the HHS Office sample exports do store these quantities, so we checked the measured values against them. Out of 3,858 stored values, 3,666 are within 2%. The takeoff's own cause finder traces 190 of the other 192 to the stored figure, not the geometry:

  • Revit's split-by-level walls carry the whole wall's area and volume on every piece.
  • Some exporters store GrossVolume and GrossSideArea with the openings already taken out, which is the net figure.
  • Revit writes half a mullion's surface area as its CrossSectionArea.

Two wall volumes are unexplained.

Does it keep the fill's promises?

The fill still promises that every written value passes its check, that no other line of the file changes, and that nothing which passed before fails after. We ran it against four real exports and 69 IDS files. It measured and wrote 3,048 values. Every one read back as passing in our checker and in IfcTester, and IfcTester found no element that passed before and fails after. On the Revit model (Schultz Residence), a cost-estimating IDS we wrote for the test went from 225 failing elements to 4. Those 4 are walls whose geometry gives no clean section, and the to-fill table says so.

A measured number is still a reading of the model, not the designer's figure. The fill's summary counts how many values were measured rather than copied or typed. The figures, the scripts and what is left (centre-line lengths, surface areas) are in the evaluation note.

All writing · More in Tools and projects · More on IDS Model Check · All tools and research