The towel dispenser that was in no room

Recessed fittings sit half inside their wall, so no room holds their middle. Sampling their whole box puts 37 of 37 in the room the model names.

A COBie handover workbook lists every maintainable component and the room it is in. Revit usually exports a component on a storey, not in a room, so IDS Model Check works out the room from geometry: it finds the room whose solid holds the component's body. To test this on 25 public models, we hide the room the file itself names and see whether the geometry finds the same one. This morning it found the file's room for 1,068 of 1,227 components. Another 64 got no room at all.

Most of those 64 were towel dispensers, grab bars and fire extinguisher cabinets. The tool had two separate problems with them.

They had no box. Revit writes these fittings as faceted surface models. Their shells are almost closed, but not quite. The takeoff engine rightly refused to cut a section through an open shell. It also threw away the shell's points, so the fitting had no extent at all. A pull request from two days ago had already fixed this ("open shells keep their box"), but it sat unmerged behind an unrelated conflict. We ported its geometry change and its test. The fix gives 362 more elements a box across the 25 files, and no volume, area or length changes.

Their middle is inside the wall. A semi-recessed towel dispenser is about 15 cm deep, and 10 cm of that sits in the wall cavity. The middle of its box falls in no room, because rooms stop at the wall face. When the usual middle-of-box tests find nothing, the tool now tests 125 points spread through the box and picks the room most of them fall in. That rule runs only when nothing else placed the element, so no component that was already placed can move.

contained components, room hidden (1,227)beforeafter
placed in the file's room1,0681,117
placed in another room9593
left blank6417

The box sampling placed 37 components, and all 37 landed in the room the model names: 25 in a dental clinic, 6 in an office, 6 in a small flat.

What's left is 17 cabinets and counter tops in two dental rooms. They sit inside each room's bounding box but outside the room's solid at every sample point. That is a question about how those rooms were modelled, and it is the next thing to look at. The full measurement is in the eval note.

IDS Model Check is free and MIT licensed, and it runs in a browser tab. The model never leaves your machine.

All writing · More in Tools and projects · More on IDS Model Check · All tools and research