IFC Quantity Takeoff reads a building model in the browser, cuts every wall, slab, covering and member from its own geometry, and checks the areas the authoring tool stored against those cuts. When a figure disagrees, the checks panel says why if it can: a wall split by level, a net area written as gross, a figure in the wrong unit. On the eight public models we test against, 117 of 12,167 stored areas still disagreed with no reason given. Today's run went through them one by one. 103 now have a cause, and in each case the file or the geometry gives the stored figure exactly, usually to four digits or more.
Slabs with holes (14). ArchiCAD's GrossArea for a slab is its outline. It equals the slab's NetArea plus the file's own "Holes Surface Area", to the last digit, on all 14 slabs in the Dutch house model: a cast ground floor storing 123.46 m² over a 27.32 m² slab with 96.14 m² of holes, and pitched roof decks with their roof-light holes. The holes are part of the slab's own outline, not separate openings, so the geometry has no "gross" to compare with, and the check could not explain the gap until it added them back.
Knee walls (12). Walls in the attic are trimmed under the roof, so their two faces differ. The stored side area is the mean of the two faces as the engine cuts them (0.0773 and 0.0449 m² give the stored 0.0611). An earlier rule found the same mean only through ArchiCAD's German property names. This model writes them in English, so the rule now uses the geometry's two faces and needs no names at all.
Coverings drawn as walls (20 figures), and one flat face (12). Façade insulation, tiling and roof upstands modelled with ArchiCAD's wall tool are exported as coverings but keep the wall's quantities: their area is the wall's centre length times its thickness. A window sill extruded along its length stores its underside, not its end profile. A concrete corbel extruded sideways stores one of its sides. Both now match one plane of the body's faces, summed plane by plane.
Walls on a curve (10). The last ten in a Norwegian school model are Revit walls built on a quarter circle. A plane cut through a curved wall gives a chord, 0.76 m² against a stored 2.59 m². Every one stores its outer face, (length + width/2 × π/2) × height, where the length is Revit's centre line, and matches to 0.000%. The engine now spots a wall that bends in plan: its side faces point in many directions and no single direction carries half their area. It says that a plane cut cannot measure that wall, and does not report a disagreement.
None of this changes a total. Every one of the 103 keeps the stored figure, which is what the bill of quantities already summed. What changes is the checks panel and the element CSV. A quantity surveyor scanning for figures to distrust now sees 14 unexplained areas in place of 117, and each of the other 103 says what the exporter measured. The 14 left are listed in the evaluation note. They are three zinc copings whose bodies the face reader cannot take apart yet, three timber frame panels, three straight walls, and two round columns that store 40 times their section.
What this does not show: three of the five causes come from one ArchiCAD model and the curved walls from one Revit model. Each needs another export to confirm it. The engine's own area for a curved wall is still a plane cut, which is wrong wherever the file stores nothing to fall back on. Measuring the curved faces themselves is the next step.
Quantities are estimates read from the model's geometry and its stored figures. They are not professional advice. Check them before you price anything.