Exterior walls and partitions are priced very differently, and in an elemental estimate they sit in different elements: B2010 Exterior Walls and C1010 Partitions in UNIFORMAT II. When the IFC Quantity Takeoff learned to group a bill of quantities by Uniformat element earlier today, it relied on the flag an IFC model can carry on each wall, IsExternal. Three of the 17 public models we test on don't set it, so their 274 walls went to "no Uniformat element".
So the tool now asks the building itself. Each wall is read in plan as a rectangle. From nine points along each face, five rays go out: straight, and 30 and 60 degrees to either side. If a ray crosses no other wall, curtain wall or glazing panel at that height, it has left the building. A wall with one face open at five or more of its nine points is exterior. Doors and windows don't let rays through, so a partition seen through a doorway still counts as inside. On the two models with no flags that we checked plan by plan (a small German house and an institute building on five levels), every placement is one I'd make, apart from two stair-core walls in the attic that could go either way.
The flags were often wrong
The more interesting result came from comparing the geometry with the flags authors did set. On 4,564 flagged walls the two agree on 3,534. Then we drew the plans of the 1,030 disagreements:
- Two models (they look like versions of the same office building) flag every wall exterior, the toilet partitions included. One house model flags 134 gypsum-board room partitions exterior. Another model flags its 67 stair and lift shaft walls exterior, in the middle of the floor.
- One residence flags 13 walls whose type is literally
Ext. Wall Sidingas interior. - Going the other way, the geometry reads linings as exterior. Revit's
Interior - Furringstud wall on the inside face of an exterior wall is modelled as a separate wall, and the test sees through it on purpose, so that the inner leaf of a cavity wall reads with its brick skin. Whether a lining is priced with the exterior wall or with the partitions is a method-of-measurement call, so the row says "inner leaf or lining" and leaves the call to you. - One model has no facade walls at all (its envelope is built from generic proxies), so its partitions look exterior.
A third witness is the wall type's own name, where it says exterior or interior. It sided with the geometry 228 times and with the flag 213 times. Neither source is reliable on its own, so the rule is conservative:
- No flag: the geometry decides, and doors in that wall follow it.
- The same flag on every wall (ten or more walls), with the geometry reading at least a fifth of them the other way: the flag carries no information and is set aside.
- Any other flag is kept. Where the geometry disagrees, the element's row in the CSV says "the geometry reads it inside the building, check it".
That last one is the useful part for an estimator. Instead of trusting a flag nobody looks at, they get a short list of walls to check before the B2010 line gets priced.
The numbers
Across the 17 models, elements with no Uniformat element dropped from 5,219 to 4,951, and level-3 codes went from 19,417 to 19,767. The 588 author-assigned Uniformat codes we compare against still match as before (482 at level 3); none of them are on walls. The full table, the plans we looked at and the cases where the geometry is wrong (knee walls under a roof, a facade not modelled as walls) are in eval/envelope-2026-11-20.md. node eval/envelope-check.mjs model.ifc --svg plans/ draws the same plans for your own model.
Nobody who prices buildings has checked these placements yet. If you do, we'd like to hear which way you put a furring wall.