The bar schedule in IFC Quantity Takeoff reads each reinforcing bar's path from the model and splits it into legs and bends. It measures every leg out to out, the way BS 8666 schedules them. Last week's check against the authors' own figures matched 30 of 33 leg dimensions. All three misses were hooks. This run looked at what a hook actually is in these files.
What changed. Each end hook now gets its angle and its tail: the straight run past the bend, which is the length a bending machine is set to. These are new columns in the CSV and show on the page under the shape. A hook is either an end bend past 90 degrees on a short end leg, or an end the file itself calls a hook. Tekla writes HOOK_START_ANGLE and HOOK_END_ANGLE on every bar, and Revit writes ISOCD3766BendingStartHook and ...EndHook. Both name 90-degree hooks too, which you can't tell from a plain leg by geometry alone.
Which end is the start? Not always the end that's drawn first. Tekla lists L-bar mark 21's long leg as A (4,650 mm), then the 190 mm leg as B, but draws the 190 mm leg first. Read naively, the file's hook angles matched the drawn bends on 42 of 45 ends. Matching the two ends either way round (the way whose angles agree, else the way whose hooks are the shorter legs) brings it to 45 of 45 across three Tekla exports and one Revit export.
What the tails show. Every 135- and 180-degree hook in these files has a 48 mm tail. That's 6 bar diameters on the 8 mm stirrups and 4 on Revit's 12 mm bar. The 180-degree one is shorter than ACI 318's minimum for that hook (the larger of 4d and 65 mm), and the schedule now notes that, naming the standard rather than judging the project's own code. Some of Tekla's 90-degree "hooks" on U-bars run down to a 7 mm straight end. The old out-to-out figure (65 mm) hid that.
Whose number? The Tekla stirrup's hook dimension E is 64 mm, but the drawn tail is 48 mm. Last week's write-up called E the straight part, and that was wrong. E is still Tekla's own figure: its length field sums A + B + C + D + 2E = 1,688 mm and rounds down to the 1,680 it states. Revit's hook parameter A is 114.3 mm (4.5 inches) on an 8 mm stirrup hook and on a 12 mm 180-degree hook alike, so it doesn't follow the drawn bar. We report the drawn tail and keep the file's figure beside it. One more Tekla 135-degree hook of another size would tell which rule gives E.
The full method and numbers are in the venture's eval note. The schedule is an estimate from the model's geometry and isn't a substitute for the engineer's or bending shop's own schedule.