When an architect sends a new issue of a model, the estimator's question isn't "what's in it" but "what changed since the last one, and what does it cost". Paid tools like CostX and Cubit answer it. The free IFC Quantity Takeoff can now too: take off the new issue, drop the old one under "Compare with an earlier revision", and you get the change on every bill-of-quantities line, priced with your rates, plus a CSV of every element added, removed, changed, moved or resized.
The obvious way to build this is to key on the IFC GlobalId, the 22-character id every element carries, and diff two lists. We tried that first on real files, and it misreports a lot.
Five exports of one house
OpeningDesign, an architecture practice, works in public on GitHub. Its Aalseth Residence repository holds five Revit IFC exports of one house, committed over five days in November 2019 (CC BY-SA; we read them but don't copy them into our repository). Between consecutive exports, a GlobalId-only comparison lists 1,011 elements as added or removed. 190 of them (19%) are the same building element:
- Four doors, a window and a wall get new GlobalIds in every export. Their Revit ElementId, which Revit writes into the IFC
Tag, doesn't change, so the report matches them by Tag within a class when the Tag is unique in both files. - Floors, roofs and walls switch between a host and its parts. Three of the exports were made with Revit "parts" on. A TJI floor then comes out as five layers named
Part:2638058and so on, and in the next export it's one slab again. The layers' volumes sum to the slab's, 30.6818 m3 both ways. The report pairs a host with the parts whose centres fall inside its box, on the same storey, when the volumes agree within 2%. That last rule needs the slack: wall layers are trimmed differently at the corners and come out 0.2 to 1.6% off their host. One more quirk: a roof's parts are exported as IfcRoof, the roof itself as IfcSlab, so the class can't be part of the test.
Without those two rules, the house's floors would appear to be demolished and rebuilt in three of the four steps.
Controls with a known answer
The opensourceBIM test files include three pairs from the HHS Office model that differ by a single deliberate edit. The report finds exactly that edit in each: a wall renamed under a new GlobalId, a column given a new id, and nothing at all in a 3,964-element file that BIMserver rewrote from scratch. The column pair hid a trap. Its "new" GlobalId is the floor slab's, so the file carries one GlobalId twice, which IFC forbids. Our first version kept the last row per GlobalId and only got this file right because the slab happens to come later in it. It now pairs a repeated GlobalId with the element of its own class and counts the repeats. A test puts them in the other order.
What the last commit changed
The last export's commit message says "updated IFC model, with updated stair". The report agrees: the stair's flights, landing and stringers are resized (Run 1 went from 1.81 x 0.99 x 1.24 m to 1.57 x 0.98 x 1.08 m), joists are re-typed, and 18 elements moved 0.16 m together. "Moved" means the box kept its size and shifted. A wall made longer is "resized" instead, so it isn't reported as moved too.
What we don't know
No estimator has read these reports yet, so "moved" and "resized" are our guess at the categories a change order needs. Elements whose faceted body keeps no faces have no box, and can only match by GlobalId or Tag. The 10 mm and 2% tolerances were picked on one house. The method, the numbers and the commands to rerun them are in eval/revision-diff-2026-11-20.md. The page's "Compare two revisions of it" button runs the same report on a hand-made sample whose every change is worked out by hand.