IFC Quantity Takeoff measures a curved wall's side area on the wall's own facets, and it only keeps the result when the faces add up to the wall's volume. It has two ways to check that. If the wall has the same section all the way up, the mean face times the width has to equal the volume. If the section changes (a thicker base, a recess along the foot), the two faces have to enclose the volume by the divergence theorem in plan. That second test works for any section, as long as every other face is level or lies along a radius.
The second check carried a guard: any body with a negative term was refused. The guard went in earlier today, while a run was chasing two half-round tunnel walls whose outer face read 5.6 m2 too big. The cause turned out to be something else (the two ends of a half ring lie on one plane), but the guard stayed, because nobody had checked what it was guarding against.
What a negative term is here
An outline that is not convex, like a ring, is split into triangles fanned out from its first corner. Some of those triangles fall over the hollow, so they count negative, and they cancel the parts of their neighbours that aren't material. About a third of a ring's triangles are negative. For the faces to come out right, the fan's diagonals have to cancel plane by plane, and the arc's chords have to keep facing outward whatever sign their triangle has.
Built walls
This run built the cases by hand. One was a quarter ring with a 0.75 m base from 1.877 to 2.3 m and the wall above from 2.2 to 2.3 m, drawn as two outlines. It also ran the same ring with the fan started on the inner arc, a half ring 20 m across, and a quarter with a recess cut by a boolean difference. Each one has 42 to 356 negative terms. Every face matched the hand-worked chords to 1e-9, and the swept volume matched the body to 1e-14. The one-section check misses these walls by 0.7 to 2.5%, so the guard had been sending them back to a plane cut, which on an arc measures a chord: 2.49 m2 instead of 13.84.
The check still says no when it should. The same wall with its ends cut square, neither level nor along a radius, misses by 28% and is refused.
The public models
Across all 28 public engine_web-ifc models, the output was identical line for line before and after lifting the guard. Instrumenting the run showed why. 45 real curved walls with negative terms already passed the simpler one-section check, so signed fans were already being read correctly in the wild. The 67 walls still refused all fail one step earlier: their facets don't face a single centre (mostly straight walls with rounded ends). None of them ever reached the swept check.
So the guard was blocking nothing in the public files. Lifting it matters for a stepped curved wall drawn as outlines, and no public model has one. The note says so, and the test that drives such a wall through the whole takeoff fails if the guard is put back.