How much of the home-battery optimiser's forecast loss does re-planning every few hours recover? On PVGIS typical-year data for three US sites, re-planning the LP every 3–12 h instead of daily adds $10–36 a year and closes at most 17 points of the gap to a perfect forecast (10 kWh, assumed tariff); energy-tou-lp-tmy with receding-horizon re-planning.
What it found
Reruns the rolling linear program of energy-tou-lp-tmy on PVGIS typical-year irradiance (Golden CO, Phoenix AZ, Seattle WA) but re-plans every 24, 12, 6, 3 or 1 hours from the actual state of charge, with a nowcast forecast added. For 10 kWh behind 6 kW PV, re-planning every 3–12 h adds $10–36 a year to the realistic controllers (Golden clear-sky-index forecast $725 → $754; Seattle $678 → $713; Phoenix $780 → $797) against perfect-forecast savings of $930, $881 and $853, so it closes at most 17 percentage points of the gap between the best fixed rule and the perfect forecast. Most of the loss is forecast loss, not execution loss. A three-hour nowcast does not beat the plain clear-sky index and hourly re-planning is no better than every 3 h; it adds 20–30 cycles a year and lowers life-limited break-even price. Differences under about $10 are inside the noise of three load seeds and one typical year. Not from a source: the tariff, synthetic load, battery cost and 4,000-cycle life (inherited, assumed), the nowcast time constant (3 h, swept at one site) and the sunlit threshold.
A figure from its own output
Paper, code and results
More in Energy supply and dense energy storage
- Does a clear-sky-index forecast rescue the optimal home-battery controller on real weather?Does a clear-sky-index forecast rescue the optimal home-battery controller on real weather? On PVGIS typical-year data for three US sites, a rolling LP fed yesterday's weather or a clear-sky-index forecast keeps 25–55% of the perfect-forecast gain over the fixed rule at Phoenix and Seattle and none of it at Golden (10 kWh, assumed tariff);
energy-tou-lp-forecaston measured-derived irradiance. - How wrong is the DC approximation of optimal power flow on the IEEE 30-, 39- and 118-bus cases?DC against AC optimal power flow in pandapower on the IEEE 30-, 39- and 118-bus cases: the DC model's cost is 1 to 3 % below the AC optimum (it ignores losses); on the 118-bus case its dispatch is feasible but costs 0.7 to 1.7 % more than the AC optimum once losses are paid, and on the 39-bus case it breaks voltage limits (15 buses at 0.6 of load) at almost no cost difference (modelled benchmark, not a measured system; tightened-limit runs often had no solution). Feeding the AC losses back into the DC model (a loss-adjusted DC) brings the 118-bus cost estimate to within 0.6 to 1.2 % of the AC optimum, but repairs only 13 to 32 % of the dispatch's excess cost and none of case39's voltage violations.
- How much grinding energy does a classifier loop save at the same product size, and does a ball-mill population balance agree with Bond's law?Ball-mill population balance (Austin form): at the same 100 um P80 a closed circuit at 278% circulating load uses 0.47 of the open-circuit energy, 1.8 to 3.7 times better across the swept mill and classifier inputs, far above Bond's 1.2 open-circuit factor and a vendor's ~10% for cement; the model's size exponent matches Bond's only at a selection exponent near 0.5.
- How much rooftop PV can the IEEE 13-node feeder take before voltage binds, and which cheap measure adds the most?Stochastic PV hosting capacity of the IEEE 13-node feeder in OpenDSS on 300 random placements: median 1,015 kW at midday minimum load, voltage binds first in 75% of placements; a 2 V lower regulator set-point adds +310 kW, while inverter fixed power factor and volt-var add about nothing once the regulators respond (modelled, not a measured feeder).
- Does regulator set-point still beat inverter volt-var for PV hosting on the IEEE 34- and 123-node feeders?PV hosting capacity of the IEEE 34- and 123-node feeders in OpenDSS (200 random placements): on the 123-node feeder a 2 V lower regulator set-point adds +790 kW to a 1,160 kW median (every placement better), inverter volt-var +100 kW and fixed power factor +180 kW; the published 34-node case has no headroom at all because its source is set to 1.05 pu (modelled, not measured feeders); over a one-minute day the set-point trades overvoltage for undervoltage while inverter reactive power cuts tap operations about 30 %.
- How much does model-predictive heating and cooling save over a thermostat on a time-of-use tariff, when the model and forecast are wrong?Does MPC beat a thermostat for a heat pump on a time-of-use tariff? On real TMY3 weather with a deliberately wrong model and yesterday's weather as the forecast it pays 10.7% less in Greensboro (4.1% in cold Sand Point), saves more with more thermal mass (6.5% to 25%), and loses the gain at an 8 K forecast error; the envelope is from published values, not a fit to measured data.
All 39 Energy supply and dense energy storage projects →
Other research topics
Proper scoring & elicitation28Effort & peer prediction9Verification games & slashing19Detection & tolerances14Markets as routers13Prediction-market design9Paying contributors8Decentralised training systems23Digital twins & sim-to-real164LLM chip design loops40Robot manufacturing loops53Ambient AI assistant46Self-replicating manufacturing34Simulation-first design64Engineered clothing45Task-specific AI accelerators40Algorithmic chip-design loops42Open-source purpose-built robots44The software-engineering loop43Adversarial human imitation41Open-source residential construction41Autonomous multi-angle capture34Sensing, imaging and 3D31Energy supply and dense energy storage39Robot societies among people31Agentic co-design of low-cost robots27Laundry-hanging robots25Machine learning on qualitative data23Robots on the building site27Civilizations & group psychology1History & human sciences1
Produced with AI assistance (Claude). Results are from the code in this repository and are simulated or stylised unless the abstract says otherwise; nothing here implies affiliation with or endorsement by any lab, researcher or company cited. MIT licensed.