How much is a home battery worth on a time-of-use tariff if it is dispatched optimally?
research/energy-tou-lp
How much is a home battery worth on a time-of-use tariff with optimal dispatch? An LP breaks even at $867/kWh for 10 kWh behind 6 kW PV, against $674 for the best fixed rule ($742 with a 4,000-cycle life); a rolling 36 h plan matches the year optimum (energy-tou with an optimiser).
What it found
Replaces the fixed dispatch rule of energy-tou with a linear program (HiGHS) over 10 seeded synthetic weather years and the same assumed three-band tariff. A 10 kWh battery behind 6 kW of PV breaks even at $867/kWh installed under optimal dispatch with perfect foresight, against $674 for the best fixed rule and $444 on a flat tariff; with life limited to 4,000 full cycles it is $742, 10% above the rule and still under the assumed $800. A rolling 36 h plan with a perfect forecast matches the whole-year optimum to $1. The optimiser adds $33 to $108/kWh across 2.5–20 kWh, and a wear-aware optimiser adds $43–58 when cycle life binds. Stylised: perfect foresight, assumed tariff, synthetic weather, crude cycle-count degradation.
A figure from its own output
Paper, code and results
More in Energy supply and dense energy storage
- How much of an optimal home-battery controller's gain survives a realistic forecast?How much of an optimal home-battery controller's gain survives a realistic forecast? With yesterday's weather or a 7-day mean as the forecast, a rolling LP saves $726 or $691 a year against the fixed rule's $694 (perfect forecast: $892); 84–101% of the gain is lost (
energy-tou-lpwith forecasts). - How much of the home-battery optimiser's forecast loss does re-planning every few hours recover?How much of the home-battery optimiser's forecast loss does re-planning every few hours recover? On PVGIS typical-year data for three US sites, re-planning the LP every 3–12 h instead of daily adds $10–36 a year and closes at most 17 points of the gap to a perfect forecast (10 kWh, assumed tariff);
energy-tou-lp-tmywith receding-horizon re-planning. - Does a clear-sky-index forecast rescue the optimal home-battery controller on real weather?Does a clear-sky-index forecast rescue the optimal home-battery controller on real weather? On PVGIS typical-year data for three US sites, a rolling LP fed yesterday's weather or a clear-sky-index forecast keeps 25–55% of the perfect-forecast gain over the fixed rule at Phoenix and Seattle and none of it at Golden (10 kWh, assumed tariff);
energy-tou-lp-forecaston measured-derived irradiance. - How wrong is the DC approximation of optimal power flow on the IEEE 30-, 39- and 118-bus cases?DC against AC optimal power flow in pandapower on the IEEE 30-, 39- and 118-bus cases: the DC model's cost is 1 to 3 % below the AC optimum (it ignores losses); on the 118-bus case its dispatch is feasible but costs 0.7 to 1.7 % more than the AC optimum once losses are paid, and on the 39-bus case it breaks voltage limits (15 buses at 0.6 of load) at almost no cost difference (modelled benchmark, not a measured system; tightened-limit runs often had no solution). Feeding the AC losses back into the DC model (a loss-adjusted DC) brings the 118-bus cost estimate to within 0.6 to 1.2 % of the AC optimum, but repairs only 13 to 32 % of the dispatch's excess cost and none of case39's voltage violations.
- How much grinding energy does a classifier loop save at the same product size, and does a ball-mill population balance agree with Bond's law?Ball-mill population balance (Austin form): at the same 100 um P80 a closed circuit at 278% circulating load uses 0.47 of the open-circuit energy, 1.8 to 3.7 times better across the swept mill and classifier inputs, far above Bond's 1.2 open-circuit factor and a vendor's ~10% for cement; the model's size exponent matches Bond's only at a selection exponent near 0.5.
- How much rooftop PV can the IEEE 13-node feeder take before voltage binds, and which cheap measure adds the most?Stochastic PV hosting capacity of the IEEE 13-node feeder in OpenDSS on 300 random placements: median 1,015 kW at midday minimum load, voltage binds first in 75% of placements; a 2 V lower regulator set-point adds +310 kW, while inverter fixed power factor and volt-var add about nothing once the regulators respond (modelled, not a measured feeder).
All 39 Energy supply and dense energy storage projects →
Other research topics
Proper scoring & elicitation28Effort & peer prediction9Verification games & slashing19Detection & tolerances14Markets as routers13Prediction-market design9Paying contributors8Decentralised training systems23Digital twins & sim-to-real164LLM chip design loops40Robot manufacturing loops53Ambient AI assistant46Self-replicating manufacturing34Simulation-first design64Engineered clothing45Task-specific AI accelerators40Algorithmic chip-design loops42Open-source purpose-built robots44The software-engineering loop43Adversarial human imitation41Open-source residential construction41Autonomous multi-angle capture34Sensing, imaging and 3D31Energy supply and dense energy storage39Robot societies among people31Agentic co-design of low-cost robots27Laundry-hanging robots25Machine learning on qualitative data23Robots on the building site27Civilizations & group psychology1History & human sciences1