Fitting a battery fade law on more cycles fixes its inputs, not the law
On 104 PyBaMM DFN cell designs, a 50-cycle fit barely moves the all-measured plating-law error on LG M50 cells; the gain goes to the forecast's inputs.
-
A ten-cycle battery fade forecast whose shape comes from the plating physics, not a fitted curve
Fixing the fade law's shape from plating kinetics beats a fitted power law on four fresh PyBaMM pools, 122 of 128 designs, halving the 100-cycle error
-
Reading the loaded charge capacity cuts the LG M50 lithium-plating forecast error by a third
A ten-cycle overpotential reading cuts a battery plating-fade forecast's LG M50 error from 28% to 21% and 25% to 16% on 128 fresh PyBaMM designs
-
Reading lithium plating at the particle surface cuts an LG M50 fade forecast's error by a third
A ten-cycle forecast of 100-cycle lithium loss in PyBaMM LG M50 models drops from 35% to 21-23% error when plating is read at the particle surface.
-
Why lithium plating slows down in LG M50 battery models: look at the particle surface, not the rest voltage
In PyBaMM's DFN model the LG M50 cells' plating slows 3.3x over 100 cycles because the surface OCP by the separator rises 38 mV, not the 0.5 mV seen at rest
-
A slower lithium-loss law fixes the battery ranking, not the screen
A + b√n lithium loss lets an electrode-balance map rank 100-cycle DFN energy at 0.61 to 0.94 on 11 of 13 pools, but it misses the best design by up to 3.2%.
-
On fresh battery pools, the map is right and the per-design fit is not
On 241 unseen designs a balance map fed the true lithium loss ranks 100-cycle DFN energy at 0.95 to 0.97; fed a ten-cycle fit, at 0.64 to 0.76.
-
One constant carries a ten-cycle fade forecast to other battery cells; a second one does not
Recalibrating one constant on 8 designs lets a ten-cycle DFN fade forecast rank three new cells at Spearman 0.76 to 0.94. Its slope does not transfer.
-
The battery map needed the size of the loss, not its order
A two-constant correction of a ten-cycle lithium-loss forecast lets a balance map rank 100-cycle DFN energy at 0.92 to 0.96 on fresh designs.
-
The battery map was right; the extrapolation was not
Ten DFN cycles over-predict the cycle-99 lithium loss up to 2.8 times, because plating slows down. The electrode-balance map it feeds is accurate.
-
Deriving the battery fade correction from the plating law works on one cell, not three
PyBaMM's plating exponential with no fitted constant cuts the 100-cycle lithium-loss error on an NCA cell from 30% to 3%, but double-counts on Ai2020.
-
The plating law predicts battery fade on fresh pools, but a better forecast can rank designs worse
With no fitted constant, PyBaMM's plating feedback predicts 100-cycle lithium loss within 2-10% on 192 fresh designs; a smaller error did not always rank better
-
Reading late battery fade off the first ten cycles
A square-root-of-cycle fade fit over DFN cycles 5 to 10, beside the raw energy, found the best Li-ion design to within 0.16% on three fresh pools.
-
Same lithium lost, different energy lost: electrode balance explains battery design fade
A no-fit electrode-balance map turned PyBaMM DFN lost lithium into energy fade within 0.05 on 34 of 40 fresh designs, ranking Ai2020 fade at 0.95.
-
The fade was plating all along
Ablating PyBaMM's degradation options on 31 Li-ion designs: plating causes 99 to 100% of the fade, SEI under 1%, and a loss variable under-counts.
-
Which battery designs can you throw away before simulating them?
Dropping electrode designs whose closed-form salt number is below -0.2 kept the best design on three fresh PyBaMM pools and cut the screen's cost by 21 to 52%.
-
Two cheap cycles can't see the plating fade
A two-cycle SPMe plating predictor on 2,324 Li-ion designs: the plating rate doesn't rank 100-cycle fade, and SPMe fails on 20% of the designs.
-
When the best battery design starts in the middle of the pack
Successive halving over resumed PyBaMM DFN runs found the best Li-ion electrode design on 2 of 3 fresh pools; on the third, the winner was 28th at cycle 10.
-
A battery-model screen on cells it never saw: the screen held, the last step slipped
A pre-registered test of when to trust PyBaMM's SPMe over DFN: all 9 mis-scored Chen2020 designs caught in 15 DFN runs; one pick 1.3% short.
-
Double the current and the cheap battery model breaks on four designs in five
When should a battery design search drop the reduced SPMe model? Current mattered as much as the cell, and the gate we wrote down picked wrong twice.
-
Should a battery design screen ever skip the cheap model? We tried a switch, and it wasn't worth it
A pre-registered test of a pilot switch between an SPMe trust rule and DFN on every design: it misfired on Ai2020, but the rule never cost more than 12% extra.
-
A battery model's trust flag, without running the model
A closed-form steady state with concentration-dependent diffusivity gives PyBaMM SPMe's minimum salt ratio to within 0.0003 on 408 fresh runs.
-
Ten cycles of the full battery model rank a hundred
A 10-cycle DFN run ranked lithium-ion electrode designs by 100-cycle energy and found the best design on three fresh cells at a fifth of the cost.
-
We built a fix for the cheap battery model's bias. On fresh designs, the old method never needed it
A gap-aware stop always found the best battery design, but the simpler rule it was built to fix never missed on fresh designs. 788 PyBaMM runs.
-
The full battery model's best fit to a real cell came from two errors cancelling
Against measured Li-ion discharges, SPMe vs DFN moves capacity by at most 1.5 points; the parameter set misses by 4.3 and self-heating matters more.
-
The best battery design sits on the salt flag, so don't throw flagged designs away
A closed-form salt flag saves no time in an SPMe/DFN battery design search, but the best design sat on it in 8 of 21 conditions.
-
Why the best battery electrode design sits at the salt edge
A cell design's 100-cycle energy splits into thermodynamic energy, utilisation and retention, which puts the optimum at the electrolyte limit.
-
Knowing where a battery model errs did not fix it. A shorter run did.
SPMe errs where its own salt runs out, but knowing that did not plan or fix a design search. A plain 10-cycle SPMe screen was the fastest yet.
-
We re-tested our own lucky finding on new battery designs. It held.
Two battery design-search tricks were found after the fact. Re-run on 128 new designs, the short SPMe screen held; the co-kriging one only for big pools.
-
A reduced battery model gets electrode designs wrong in two ways, and it reports both
On five PyBaMM cells, SPMe's errors are salt depletion or a solver stop. Flag both and verify bottom-up: every mis-scored design found, no calibration runs.
-
A battery-model trust test moved to two new cells: the ranking holds, the cut-off does not
On two new PyBaMM cells, SPMe's salt depletion still finds the designs it mis-scores (AUC 0.995), but the first cell's cut-off misclassifies 20%.
-
Multi-fidelity Bayesian optimisation for battery design loses its race at the start line
Co-kriging BO over a cheap and a full battery model lost to GP-EI because of its random start. Started from cheap runs, it kept pace with the best screen.
-
When a battery model run fails, ask the solver first: SPMe's stops and failures differ
Re-solving 67 failed SPMe battery-model runs: tight tolerances fix early stops; runs whose salt goes negative stay broken.
-
Planning a battery design screen: where the cheap model errs matters more than how much
A noise-model formula predicts how many full DFN runs a cheap battery screen costs. It plans screens right 14 times in 16, and fails on SPMe.
-
A battery model can be wrong by 40 Wh/kg and still be a perfect screen
Which part of a cheap battery model's error costs full DFN runs in a design search? Only what is left after an affine fit, and for SPMe that is salt depletion.
-
A cheap battery model can tell you where it's wrong, but in our test it wasn't the cheap part
SPMe's own minimum salt concentration flags the Li-ion designs it mis-scores (AUC 0.997), but a 2-cycle DFN run costs about the same: the cost is in the cycles.
-
The best battery-model screen is not the fastest way to the best cell
On 128 simulated Li-ion electrode designs, a crude whole-pool screen beats Bayesian optimisation by 30%, and the best-ranking screen loses to it.
-
Stop the full battery model early instead of swapping in a cheaper one
A 10-cycle DFN run ranks 49 Li-ion electrode designs like a 100-cycle DFN run (Spearman 0.977); a full SPMe run reaches 0.834 in the same time.
-
Ten cycles of the full battery model rank cell designs better than a hundred cycles of the fast one
On 128 Li-ion electrode designs, 10 cycles of DFN rank them by 100-cycle energy at Spearman 0.96; 100 cycles of SPMe, same cost, reach 0.64.