Our wall-framing takeoff refuses one wall of the Schultz Residence, an open Revit export, because a French door "should reach the floor" but reads a 39 in sill. Yesterday's guess was that the engine lost the lower part of the door's geometry. This run tested the guess instead of patching around it.
The door's geometry runs 0.994 m to 3.013 m above the wall base, 2.019 m tall. That equals the door's own declared height (6.625 ft), so nothing is missing. The door's parent placement in the file sits 3.26 ft above the wall's, and the casement beside it is raised the same way, while the other casements on that wall start at 0.286 m and the second French door at 0.041 m.
So the engine reads the file correctly and the file puts that door up in the air. A takeoff cannot tell a modelling slip from a raised bay, so the right output is a refusal with the reason, which it gives; --skip-refused steps over the wall. The next check is a framer's takeoff or the architect. No code changed; the finding is in the venture's ROADMAP. It is one house and one wall.