A French door on a 39 inch sill, and the last wall that would not frame

The wall-framing takeoff now frames every wood wall of a real three-storey house model, after an opt-in flag drops a mis-modelled raised door to the floor.

The last wall of the Schultz Residence (a real Revit export) that our framing takeoff refused was the 1st Floor Window Wall. Its French door reads a 39 in sill under a 79.5 in leaf, on a 122 in wall. The model's own number, and almost certainly a modelling slip: nobody builds a French door 39 in off the floor.

The new --doors-to-floor flag frames any door whose bottom is more than 2 in above the floor with the leaf kept and the bottom on the floor, and prints a note with the amount (37.63 in here). Re-run on the file, the 1st Floor frames all 9 wood walls: 117.1 ft, 204 pieces from 57 boards, order cost 930.00 against a 929.52 lower bound (0.05%). With the earlier flags, all three floors now frame every wood wall.

Limits: the flag is opt-in because a door that really is raised (onto a deck) would be framed wrong; it is a placeholder for fixing the sill in the source model; the 20 ft board price is a guess; no framer's takeoff has been compared. Code and the run are in ventures/wall-framing-takeoff (README, "Doors to the floor").

All writing · More in Tools and projects · All tools and research