The Schultz Residence is a real Revit house, and the framing takeoff still refuses its upper floors. Looking at why, two of the walls turned out to be door frames the architect modelled as walls: one 37 inches long holding a 32 inch door, another 54 inches long with a door 45 inches wide. No framer builds those as walls, and the takeoff cannot fit king and jack studs into them.
ifc-engine now has --drop-frame-stubs, off by default. It drops walls under 1.2 m long that are more than 75% door or window, and says how many it dropped. On the 2nd Floor that clears one of three refusals. The other two (a door at 0 in on another wall, two tees 0.1 in apart) and both 3rd Floor refusals are still there, and the 3rd Floor door sits on a 3.5 m wall, so it is a different problem. The thresholds come from this one house, and no framer's takeoff has been compared with the result.
Notes and the test are in ventures/wall-framing-takeoff/README.md and ifc-engine/tests/fixtures.rs.