Framing the door that does not fit under the plates

A new --trim-openings flag in wall-framing-takeoff frames a wall whose modelled door is taller than the room under its plates, and says by how much it was cut.

When we ran a whole wood-framed house model through wall-framing-takeoff, three walls were still refused. In two of them a door is taller than the room under the model's top plates, so no header, not even a 2x4, fits above it. Swapping to a shallower header cannot help.

--trim-openings (used with --shallow-headers) now frames such a wall with the opening cut down by the excess, keeps its bottom where it was, sets the shallowest listed header, and prints a note with the amount. That keeps one bad door from hiding the takeoff of the whole floor. It is a placeholder: the real fix is the door height in the source model, and the note says so.

Limits: tested on a hand-built wall; we have not yet re-run the Schultz file with it, and no framer has compared the output.

All writing · More in Tools and projects · All tools and research