S235JR weighs 8,000 kg/m3 in one Tekla model and 7,850 in another

The free IDS checker now writes missing Qto_ NetWeight values. The density comes from the model, not a textbook table, which would have got 152 of 1,145 right.

Steel is bought, lifted and shipped by the tonne, so an Information Delivery Specification (IDS) for a steel or precast package nearly always asks every beam, column and member for Qto_BeamBaseQuantities.NetWeight. If the model doesn't carry one, the check fails, and someone has to type the weights in.

IDS Model Check can already measure missing volumes, areas, lengths and surface areas from each element's geometry and write them into a copy of the model. Weight was left out because no geometry defines it: you need volume times density, and IFC carries a density only sometimes.

How do exporters get their weights?

Three of the 28 public models we test against store weights, all from Tekla Structures. For each element that stores both a weight and a volume, we divided one by the other and grouped the results by material:

ModelMaterialkg/m3Stored weights that agree
Mini ProjectSTEEL/S235JR8,000178 of 178
Mini ProjectCONCRETE/BETON (and five more)2,450491 of 491
Mini ProjectCONCRETE/GEWELF2,40027 of 27
Mini ProjectTIMBER/HOUT600324 of 324
M3D-CON-CDSTEEL/S235JR7,85056 of 56
M3D-CON-CD, M3D-CONCONCRETE/Concrete_Undefined2,40069 of 69

So every one of the 1,152 stored weights is the element's stored volume times a single density for its material, to within 0.5%. The catch is that the same steel grade weighs 8,000 kg/m3 in one office's model and 7,850 in another's. Each office set up its own material catalogue.

A tool using textbook densities (steel 7,850, concrete 2,400, timber 500) would have got 152 of the 1,145 weights right. The rest would be off by 1.9% (steel) to 20% (timber), which matters if those figures feed crane picks or a supplier's quote.

What the checker does now

The density comes from the model or from you, and is never assumed:

  1. Your table. A material,density line for each material, named as the model names it (STEEL/S235JR,7850). On the page it goes in a box under "Measure missing Qto_"; on the command line it's --densities rates.csv.
  2. The model's own material properties. Pset_MaterialCommon MassDensity (IFC4) or IfcGeneralMaterialProperties (IFC2x3). ARCHICAD writes 0 for every material that has no density set, so a 0 is ignored.
  3. The model's own stored weights. If some elements of a material store a weight and all of them imply the same density, that density fills in the elements of that material that don't store one.

The volume used is the element's stored NetVolume when it has one, because that's the figure the exporter weighed, and the volume measured from its geometry when it doesn't.

How we checked it

  • Held out: hide the weights of half the elements, learn densities from the other half, then predict the hidden half. 562 of 562 came out within 0.5%.
  • End to end: rename every stored weight on the three models, ask the fill for NetWeight with the densities typed in as a table, and compare what it writes with what Tekla had stored. All 1,146 came back (1,021, 20 and 105), every one within 0.001%.

What we couldn't check: no public Revit or ARCHICAD export in the corpus stores a weight, so we don't know whether those tools weigh the stored volume or the geometry. The method, the scripts and every number are in the evaluation. The checker is free, MIT licensed, and runs in your browser, so the model never leaves your machine.

All writing · More in Tools and projects · More on IDS Model Check · All tools and research