Tekla writes its Qto_ quantity sets as property sets, and fills used to skip them

Tekla Structures stores every Qto_ set as an IfcPropertySet. IDS Model Check's fill now measures values for those sets too, within 2% on 551 of 583.

IFC has two kinds of containers for an element's numbers. Properties (fire rating, load bearing) go in an IfcPropertySet. Quantities (length, area, volume) go in an IfcElementQuantity, and the standard ones have names that start with Qto_: Qto_WallBaseQuantities, Qto_ColumnBaseQuantities and so on.

Tekla Structures doesn't follow that split. We looked at four public Tekla exports, including one Tekla 2026 model exported as IFC2X3, IFC4 and IFC4X3. All of them write every Qto_ set as a property set: 661 sets on elements, and not one IfcElementQuantity. Two Allplan 2024 test exports do the same, with German property names (Länge, Dicke, Höhe) that no Qto_ template defines. Allplan 2025 writes proper quantity sets.

This doesn't break an IDS check. IDS 1.0 property facets read both kinds of set, and so do IDS Model Check and IfcTester. It did limit the model fill, though. When a model fails an IDS because a quantity is missing, the fill can measure the value from the element's body and write it in. That only happened when the element held the set as a quantity set, or had no set of that name at all. On a Tekla model the set always exists as a property set, so every missing NetVolume went to the "type this in yourself" table. The column's body was right there to measure.

Does the measurement agree with Tekla?

Before writing into Tekla's sets, we compared the geometry reading with what Tekla already stores in them. We converted Tekla's millimetres to metres and compared element by element:

  • Tekla 2026 as IFC4: 150 of 151 values within 2%.
  • The same model as IFC2X3: 165 of 183. As IFC4X3: 140 of 147. The beams that differ in those two exports agree in the IFC4 export, so the difference comes from how each export writes the bodies, not from the measurement.
  • An older Tekla export: 96 of 102, leaving out wall side areas.
  • In all: 551 of 583.

Wall side areas are the exception. Tekla stores NetSideArea as both faces of the wall: 203 m² on a 28.6 m by 3.6 m wall. The Qto_ definition means one face. Tekla's figure isn't exactly twice one face either; it is 2.2% off. We couldn't find the rule behind it, so the fill doesn't measure side areas into a Tekla-style set. Writing either figure would disagree with the file's other walls.

What the fill does now

When the set exists as a property set, the fill writes the value into it as a property of the right measure (IFCVOLUMEMEASURE(0.0754)), in the model's own units, rounded to six significant figures. It doesn't add a second set with the same name beside it.

We tested it with a cost-estimating IDS that asks walls, slabs, columns and beams for their volumes and areas. On the three Tekla 2026 files, failing elements went:

Exportbefore the fillold fillnew fill
IFC2X3972917
IFC41174937
IFC4X31164836

IfcTester counts the same failures on all six filled and unfilled files. The walls still failing are missing side areas, which the fill left alone on purpose.

Method, numbers and file sources: ventures/ids-model-check/eval/qto-psets-2026-11-23.md. The models come from two public repositories and are fetched, not copied, by eval/fetch-qto-psets.sh.

Estimates from the model's geometry, not professional advice: check measured quantities before using them for costing or procurement.

All writing · More in Tools and projects · More on IDS Model Check · All tools and research