IDS Model Check can fill in missing Qto_ quantities by measuring each element's geometry. One public test model lets us check that against itself. A Tekla Structures 2026 model was exported three times, as IFC2X3, IFC4 and IFC4X3. Same beams, same walls, three files.
The measurements should have agreed, and they didn't. In the IFC4 file, 150 of 151 measured values were within 2% of what Tekla stored. In the IFC2X3 file only 51 of 68 beam volumes were. Matching every element across the three files by its GlobalId turned up 53 values that agreed in one schema and not in another.
The beams: where did 5.9% go?
The worst case was a 5 m HEA300 pile. In IFC2X3 its body is the standard parametric I-section, with the 27 mm radius where web meets flange. In IFC4, Tekla writes the same pile as a 24-point mesh, and the mesh has square corners.
- With the fillets: 11,253 mm² x 5 m = 0.05626 m³
- Without them: 10,627 mm² x 5 m = 0.05314 m³
Tekla's own Quantities set on the pile holds both. GrossVolume is 0.05625, the catalogue section. NetVolume is 0.05314, the modelled solid, which has no fillets. So the IFC2X3 measurement was the true steel volume, and Tekla's NetVolume was the other figure. Neither was a bug. Together they meant a NetVolume we filled into a Tekla model would come out 5 to 6% above the ones Tekla wrote for the beams beside it.
The fix follows Tekla's convention, for Tekla models only. When a Tekla column, beam, member or pile is a single extrusion of a parametric section, the NetVolume we offer leaves out the fillets. GrossVolume keeps them.
We checked it on Tekla exports from the web-ifc test set, which played no part in finding the rule. The rule changes 109 members that also store a NetVolume. All 109 now match the stored figure, against 37 before (the 37 were sections whose fillets are under 2% of the area). It made no match worse.
The walls: lying on their side
The second cause had nothing to do with steel. Tekla's IFC4 export draws a wall as a box in a frame whose own y axis points up, with no axis line. The checker read a wall's length and height only when its own z pointed up, so these walls got no reading at all.
Now such a wall is turned upright before it's measured. That only happens when the wall runs along its own x, which is how Tekla draws one. The rule was first written without that condition, and the corpus check caught it. Another Tekla model has four 1.45 x 1.5 x 3 m concrete piers that stand on their own x. Tekla stores their "Length" as the 3 m upright side, which goes against the standard's definition, so those are left for a person. Across all 40 public files, 37 walls get turned. All 74 of their stored lengths and heights match.
Where that leaves Tekla models
Across the four public Tekla exports, 649 of 657 measured values are now within 2% of what Tekla stored, up from 551 of 583. That counts values filled into Tekla's own Qto_ property sets. One gap is left: 14 single IPE80 members that Tekla classes as railings get no reading in IFC4. The railing reader looks for a top rail, and a single member doesn't have one.
The method and every count are in eval/beam-schema-twins-2026-11-23.md. The checker is free, runs in your browser, and the model never leaves your machine.