A foundation estimate is priced off a few figures per footing: how long, how wide and how deep it is, its section, and the area of its faces (the formwork). IFC keeps them in Qto_FootingBaseQuantities. An IDS file for a structural model can ask every IfcFooting for them. When a model doesn't have them, IDS Model Check could only list each footing in a to-fill table. It now measures them from the footing's own body and writes them into a copy of the model.
Finding the gap
The run started by counting. It listed every stored Qto_ figure on 32 public IFC files (the web-ifc test models and four opensourceBIM exports), then took out the ones the fill could already measure. What was left: openings' sizes, assemblies' widths, railings' lengths, and footings. The footings were the clearest case: 88 of them in two Tekla exports of one project, every one storing all six figures, and no way to fill any of them.
What Tekla calls a length
The obvious reading of "length" for a pad footing is its longer side in plan. Tekla doesn't use it. Tekla models a pad like a short column, so its Length is the depth: a 14.9 x 7.8 m pad stores Length 1.2 m. Width and Height are the two plan sides. A strip or a wall-like footing is modelled like a beam, and its Length is the longest side of the smallest box around it, the same rule Tekla follows for its cut steel members. That holds for tapered strips too, whose section at mid-length covers a quarter of the box. On all 88 footings, Width is the side that lies along the part's own y axis.
So the measuring follows Tekla's rule. It finds the box flush with the body's faces and checks whether its thinnest side is upright. If so it's a pad, and Length is the depth; otherwise Length is the longest side, as long as that side is clearly longest. CrossSectionArea is the volume over the depth, offered only when the body really is a prism through its depth. That keeps the 98.5 m² of a trapezoid pad rather than its 116 m² box. Both surface areas are the total area of the faces, which is what Tekla writes for its members as well.
Two figures that are not measurements
On the 23 footings that aren't pads, two of Tekla's six stored figures don't match anything in the body. CrossSectionArea is always Width x Width: 0.4225 m² on a 0.65 x 5 m section. GrossSurfaceArea is always Length x Height: 31.5 m² on a body whose faces add up to 69.2 m². We checked all 23, and the pattern holds on every one. The fill doesn't copy those slips. It holds the cross section back for a person to fill, and for the gross surface it writes the faces' total, which is what the definition asks for.
Results
| Figure | Offered | Within 1% of Tekla's |
|---|---|---|
| Length, Width, Height | 88 each | 88 each |
| CrossSectionArea (pads) | 65 | 65 |
| OuterSurfaceArea | 88 | 88 |
| GrossSurfaceArea | 88 | 65 (the 23 others are Tekla's Length x Height) |
We then hid every stored figure and filled the models from the bodies alone. That wrote 505 values. The checker's own read-back passes all of them, and IfcTester, the reference checker from IfcOpenShell, moves exactly those 505 from failing to passing and fails nothing new.
Limits
This is one authoring tool and one project. Another Tekla office's export would test the pad and strip rule. An ARCHICAD or Revit export that stores footing quantities would show what those tools call a footing's length, so for now they get only the total surface area, the one figure whose meaning doesn't depend on that choice. The numbers and the scripts are in the evaluation. Next in the count are openings' sizes: over 1,300 stored by ARCHICAD and Revit.