Three Revit exports, three answers for a door's height

IDS Model Check now fills ARCHICAD doors' and windows' Qto_ sizes from the opening each fills, 377 of 380 exact. Revit's exports disagree, so they get none.

A door and window schedule, a glazing takeoff or an energy model reads four figures off every door and window: Width, Height, Area and Perimeter from Qto_DoorBaseQuantities or Qto_WindowBaseQuantities. An IDS file that asks for them fails every element of an export that left them out. Until today, IDS Model Check's model fill could measure walls, slabs and beams from their geometry, but sent every door and window to a table for a person to type into.

A door seems to carry the answer already. IFC gives IfcDoor and IfcWindow two attributes, OverallWidth and OverallHeight. The body is there too, and so is the opening the door fills in its wall. So which of the three did the exporters measure? I checked against every stored figure in the public test models of two open repositories (opensourceBIM's IFC-files and That Open Company's web-ifc test set).

ARCHICAD measures the opening, exactly

On three ARCHICAD exports, all four figures equal the opening's on 315 of 315 elements, to the last digit. The opening is taken into the door's own placement, where x is the width and z the height. The two round windows in the FZK-Haus model were the giveaway: 1 x 1 m, Area 0.7851 m², which is the circle's, and Perimeter 4.0 m, which is the bounding square's. Width times height would have said 1 m², 27% too much. The opening's own section across the wall gives the right area. Twice width plus height gives the perimeter ARCHICAD wrote.

Revit gives three different answers

The three Revit exports each store something else:

  • Revit 2010 (the HHS Office architect model) stores the OverallWidth and OverallHeight attributes. Four steel-framed doors store 0.9339 m, a width that neither the attributes (0.885 m) nor the opening give.
  • Revit 2019 (a Norwegian school, ARK_NUS) stores neither. Doors typed 10x21M store 0.99 m in a 1.01 m opening, and 14x14 windows 1.39 m in a 1.42 m opening. Its Area is larger than width times height: 2.86 m² on a 1.42 x 1.42 m window.
  • Revit 2022 (a small German flat) stores the opening's width. On windows it stores the opening's height too, 1.35 m, where OverallHeight says the frame's 1.365 m. On doors it stores the leaf's nominal height, 2.05 m (the type's Rohbauhöhe), inside a 2.15 m opening.

Any single rule writes wrong figures into at least one of these three. So the fill writes none for Revit and leaves those rows in the to-fill table. A wrong number that passes an IDS check is worse than a gap the check reports.

What it does now

For ARCHICAD exports, a door or window that fills exactly one opening gets the four figures from that opening. It gets nothing if the opening is more than 1% off the element's own attributes. Four of schependomlaan's windows are why: 0.9 x 1.5 m windows sit in a 1.53 x 2.637 m opening and store a 0.30 m width, which no reading reproduces. On four public ARCHICAD exports, 380 elements are offered. All 380 are within 2% of the stored figures, and 377 match to the last digit.

To test the fill from end to end, I renamed every stored quantity so the model no longer had them, then asked the fill for all four. It wrote 1,824 values, and the 1,520 that have a stored figure all match it. IfcTester, buildingSMART's reference checker, takes exactly the written elements from fail to pass.

It is on in the CLI with --fill --from-geometry and on the page with the Measure missing Qto_ checkbox. The full write-up, with every table, is eval/door-window-quantities-2026-11-22.md. Still open: a rule for Revit, and the 390 of schependomlaan's 464 doors and windows that fill no opening at all.

All writing · More in Tools and projects · More on IDS Model Check · All tools and research