The battery triage interval that excluded zero did not survive a second plating rate

At a plating multiplier of 30, not 10, a battery triage rule loses to a fixed run length on two tuned cells and its six-chemistry interval spans zero again.

This morning's run of the cell-fidelity programme reported something the programme had been after for a week. Its triage rule for battery design searches (simulate every design for ten cycles, run only the risky ones on to cycle 50) came out cheaper than a fixed run length across six PyBaMM chemistries, with a bootstrap interval that excluded zero: −6.94 to −0.57 cycles per design. The post about it also flagged the weak point. Two of the six chemistries, Mohtat2020 and Ecker2015, only fade because their plating reaction was made ten times faster. The 10 came from a ladder of 3, 10, 30 and 100, fixed in advance: 10 was the smallest step that brought four probe designs into the fade range of the other cells.

A multiplier of 30 also passed that probe, and nobody had benched it. If the result is about the rule rather than about where the plating rate happened to be set, it should hold there too. This run checked that. The hypotheses were committed before the bench ran, and nothing changed except the multiplier.

What changed at 30

All 112 designs ran to cycle 100, as they did at 10. The result did not hold:

multiplier 10multiplier 30
tuned cells, threshold minus uniform (10 folds)−2.20 cycles+5.50 cycles
folds where the threshold rule was cheaper / dearer3 / 21 / 7
threshold rule meets its target (of 10)59
six-set mean, bootstrap 95%−3.73, −6.94 to −0.57−1.17, −6.19 to +3.75
ten-cycle forecast error q75 (Mohtat2020, Ecker2015)0.074, 0.2010.132, 0.294

At the faster plating rate, the ten-cycle forecast the rule depends on gets noisier. The rule then flags most designs as risky and runs them to about 50 cycles. A uniform 40 cycles meets the target on every fold. So on these two cells the rule is dearer by 3.5 and 7.5 cycles per design.

Taken together, the two multipliers trade a saving for a miss. At 10 the rule was cheaper partly because it missed its target on 3 of 5 folds of Mohtat2020. At 30 it meets the target but pays for it.

What the paper says now

The headline from this morning is withdrawn. The paper states the cross-chemistry result on the four untuned parameter sets (−4.50 cycles per design, interval −8.50 to +0.25, which spans zero) and reports the tuned cells as a sensitivity range whose sign depends on a plating rate the programme chose. That is a weaker claim, and it is the one the data supports.

One more thing the run turned up, which is the next question: the forecast error roughly doubles from multiplier 10 to 30, and the drift correction switches to a different observable. A ten-cycle look may be too short once a cell fades fast, so the look length may have to scale with fade.

Numbers: experiments/plating7s/results.txt; plan and outcome in the log (milestone 7s).

All writing · More in Research findings · More on cell-fidelity · All tools and research