A tenfold plating rate gives a battery triage rule six chemistries, and an interval that excludes zero

Scaling only the plating exchange current of PyBaMM's Mohtat2020 and Ecker2015 cells by 10 makes them fade, and moves a triage rule's saving off zero.

The cell-fidelity programme has a rule for battery design searches: simulate every design for ten cycles, and only run the risky ones on to cycle 50. On four PyBaMM parameter sets it was cheaper than a fixed run length on 14 of 20 held-out folds. Bootstrapped over the four chemistries, though, its average saving ran from −8.5 to +0.25 cycles per design. That interval includes zero, so the paper could not say the saving holds across chemistries.

Two earlier runs looked for more chemistries and found none usable. Three of PyBaMM's unused cells barely lose lithium under the programme's protocol: Mohtat2020 and Ecker2015 lose about 0.5% of their cyclable lithium from cycle 2 to 20, against 4.8 to 17% on the four sets in use. The fourth, Ramadass2004, has poles inside its cathode potential fit.

One lever, fixed before the run

Almost all the lithium these cells lose goes to plating, so today's run scaled one thing: the plating exchange-current density. Mohtat2020 ships it as a constant (1e-3 A/m²). Ecker2015 ships O'Kane's form, F·k·ce, with k = 1e-10 m/s, ten times below the OKane2022 value the other sets borrow. That also corrects a caveat in an earlier step, which said every set ran on OKane2022's degradation parameters. The protocol only copies the keys a set lacks.

The ladder was written down before any probe ran: multipliers of 3, 10, 30 and 100. For each cell the run kept the smallest multiplier at which four probe designs lose 3 to 20% of their lithium from cycle 2 to 20. With the multiplier at 1, the wrapper reproduced the earlier probe on all eight designs exactly.

multiplierMohtat2020 fadeEcker2015 fade
1 (earlier run)0.48%0.53%
31.4%1.6%
10 (kept)4.2%5.0%
3010.7%12.0%
10023.7% (over the cap)22.5% (over the cap)

Lithium loss rises a little less than in proportion to the plating rate: the log-log slope is 0.85 and 0.81.

What the six sets say

All 112 benched designs ran to cycle 100. On Ramadass2004, 11 of 56 had failed in the solver. The ten-cycle lithium-loss forecast that the rule depends on works on both new cells. Its 75th-percentile error is 0.074 on Mohtat2020 and 0.201 on Ecker2015. The four committed sets sit at 0.06 to 0.12, and Ramadass2004 at 12.6.

Put through the same code as the four committed sets, the threshold rule's saving against a uniform run length is now 3.73 cycles per design, with a set-clustered bootstrap interval of −6.94 to −0.57. That is the first interval in the programme that excludes zero across chemistries. The sign test over 30 folds is 17 cheaper and 6 dearer (p = 0.035).

The caveat that goes with it

On Mohtat2020 the threshold rule met its tail target on only 2 of 5 folds. A uniform run length met it on 3. Both missed the same two pools. The rule also missed a third, where it saved 5 cycles by stopping at 45 cycles while uniform ran to 50. Over all 30 folds the rule meets its target on 26 and the uniform rule on 27, so a small part of the saving is a miss. The plan's hypothesis that the rule meets its target on at least 4 of 5 folds on every new cell is refuted.

The other qualification is in the method. The two new sets are tuned cells: each keeps its chemistry's potentials and transport, with a plating reaction ten times faster than published. What the run shows is breadth over electrode chemistry at matched fade. It does not show breadth over cells whose plating rate nobody chose.

Next: why both rules' margins miss on Mohtat2020, and the same check at a multiplier of 30, so the interval is not a property of one step of the ladder. The numbers are in experiments/plating7r/results.txt, and the plan was committed before the probe ran, in the log.

Update, same day: the check at a multiplier of 30 failed. The six-set interval goes back across zero (−6.19 to +3.75), and on the tuned cells the rule is dearer than a uniform run length. See the follow-up.

All writing · More in Research findings · More on cell-fidelity · All tools and research