A robot that shares a corridor with people should be tested in a crowd model that walks like people do. Our corridor twin is collision-free speed, a JuPedSim crowd model, checked against the HERMES corridor experiments run at Jülich in 2009. It reached the densest real run (1.72 people per m²) last step. It was wrong in two ways, though. At 0.8 per m², adding a walker barely slowed anyone down, and above 1.3 per m² people crossed too quickly.
This step tuned two knobs together: the model's time gap (how far ahead, in seconds, a walker keeps clear) and the body radius. We ran a 5 × 4 grid of 2,160 simulations, with nine predictions written down before any number came back. Each pair was scored on how closely it matched the real time-to-cross curve and on how closely its slope matched.
What came out:
- The best pair is a long time gap with a thin body (0.8 s and 0.15 m). On 16 fresh seeds it matches the dense run: 10.56 s to cross 8 m against a real 10.61 s. Taking away 20% of the walkers saves +1.16 s, against a real +1.38 s (interval +0.96 to +1.85).
- The light run comes out too slow. At 0.84 per m² this twin takes 7.92 s where people took 6.55 s. The marginal walker still costs too little there: +0.18 s against a real +0.41 s.
- Across the whole curve it does no better than the old one-knob twin (curve gap 1.06 s against 1.01 s). That holds on held-out runs where people were told which exit to use as well.
- Wider bodies jam instead of slowing smoothly. With a radius of 0.25 m or more and a time gap of 0.3 s or more, the corridor clogs, and in the worst pair 32 of 108 runs saw no one cross.
Three of the nine predictions held: the replication check, and the two about the dense end. The ones that failed say something about the model. Collision-free speed keeps a walker at full speed until the gap ahead runs out. A setting that slows people enough in a dense crowd therefore slows them everywhere, and no setting makes them ease off early at moderate density, as real walkers do.
What we will use it for: robot experiments at the dense run's density can use this twin, because there its level and its marginal cost both match the real runs. At 0.8 per m² no setting we tried is good enough. That operating point needs a model whose speed falls smoothly with spacing, and it is the next step.
Code, data and the full results are in research/society-lanes; the predictions and the outcome are in its research log.