Correct a ten-cycle battery fade forecast, don't lengthen it

On 200 PyBaMM DFN designs, a ten-cycle forecast bent by the early lithium-loss curve beats a straight 50-cycle look when plating throttles itself.

The last cell-fidelity post found why the programme's ten-cycle forecast of lithium loss gets worse on cells with a faster plating reaction. The plating slows itself over 100 cycles, which bends the loss curve, and a straight line through the first ten cycles overshoots. A longer look did not help: even at 50 cycles the straight line was worse than the slower cells managed in ten.

That post ended with a remedy to test. Find an early sign of the throttle, inside the first ten cycles, and use it to bend the forecast. This run tested it on data already on disk (200 designs, no new simulation), with the hypotheses committed before the numbers were computed (log, milestone 7u).

The early sign was already in the recipe

The candidate was the bend of lithium plated over the first ten cycles: plating in cycles 6 to 10 over plating in cycles 2 to 6, on a log scale. Several steps earlier (milestone 7c) the programme had defined an observable called O3. It is the same ratio, but on all lithium lost, not just the plated part. On these two cells plating is 99.6 to 99.9% of what they lose, so the two should match. They do, to within 0.0003 on every one of the 200 designs.

So the question became: does 7c's existing correction, a least-squares line from O3 to the design's drift, fix the faster cells? Each pool of designs was held out in turn and predicted from the other four.

cellplating multiplierstraight ten-cycle lineten-cycle line, correctedstraight 50-cycle line (7t)
Mohtat2020100.0450.0380.049
Mohtat2020300.1050.0380.061
Ecker2015100.0980.0960.076
Ecker2015300.2490.0720.131

Median error in lithium at cycle 99, |ln(forecast / true)|, held out by pool. The last column is from the previous step and was not part of this step's plan.

At the faster plating rate the correction removes 64% and 71% of the error. The corrected ten-cycle forecast beats both the slower cells' straight line and a straight line through 50 cycles. At the slower rate there is little drift to correct, and the gain is small.

What did not work

The plating-only version never beat the existing correction. At multiplier 30 the two give the same forecast (medians equal to 0.00002), because the correction already picks O3 on every fold. At multiplier 10 the correction picks a different observable, the depth of the first cycle's plating, and the plating bend is a little worse. Putting both bends into one line helped on one cell and hurt on the other. The two numbers differ by less than 0.0003, so the second slope is fitting noise.

That is the useful part for anyone running a battery design search with a ten-cycle screen. You don't need to read plated lithium, which a simulation gives for free and a real cell does not. The bend of capacity loss over the first ten cycles carries the same signal.

Limits

Both cells have a plating rate the programme chose so that they fade like the other parameter sets, so this is PyBaMM's plating law at two rates, not a measured cell. Five folds per cell. The next step is the one a design search pays for: does the corrected forecast make the triage rule cheaper than running every design for a fixed number of cycles on these cells? At multiplier 30 it was 5.5 cycles per design dearer with the straight line.

Code and numbers: experiments/bend7u/.

All writing · More in Research findings · More on cell-fidelity · All tools and research