ARCHICAD and Revit disagree on a clipped wall's height, and the IFC file says which one wrote it

Which Qto_ Height ARCHICAD and Revit store for a wall a roof cuts, checked on 16 public walls, and how the free IDS checker now fills it.

The free IDS checker can write missing Qto_WallBaseQuantities values into a copy of an IFC model, measured from each wall's own geometry (brep walls and walls with no axis was the last step). Until today it skipped one case on purpose: a wall that a sloped roof or a slab cuts. Such a wall has two heights, and exporters disagree about which one is "the" Height.

Two exporters, two answers

Take a gable-end wall 3.5 m tall where the roof cuts its top down to 3.39 m. On the public FZK-Haus model, ARCHICAD stores 3.387 m: the cut wall's highest point above its base. On the HHS Office construction model, Revit stores the extrusion depth, the height of the wall before the roof took anything off. The Qto_ definition ("usually the extrusion depth") allows both readings.

We checked every clipped wall in 15 public models that stores a Height:

Authoring toolClipped walls with a stored HeightMatched by its own conventionMatched by the other one
ARCHICAD11112
Revit550

So the convention follows the tool, and the tool is written in the file. Every IFC element has an owner history that names the application that made it. The filler now reads that name and writes the figure that application would have written: the highest point for ARCHICAD, the extrusion depth for Revit. For any other tool it still writes nothing and leaves the row in the to-fill table for a person, because no public model shows what those tools store.

A corner the first pass missed

Two of the eleven ARCHICAD walls first came out 2% low. Both are 2 m walls mitred at each end under a hip roof. Their highest point, 2.0257 m, sits right at a mitre's acute corner. The measurement drew vertical lines on the two faces and the middle plane, nudged a hair inside each vertex along the wall, and none of those lines falls inside that corner. Lines through every vertex, nudged into each quadrant around it, now return 2.02569 m, which matches the stored figure to five decimals. The nudge is deliberately not diagonal, since a 45-degree mitre face would contain a diagonal line exactly.

What did not work: Revit's own constraints

Revit exports also carry each wall's constraints: base level, top level, the offsets, and an "unconnected height". Adding those up looked like a way to recover the uncut height of Revit walls exported as breps, which no longer contain an extrusion. Against 358 stored Heights the constraints were right where nothing unusual was going on (84 of 84 on one model). They were wrong on every wall whose top is attached to a roof (0 of 67), and on walls that Revit splits by storey on export: a 10.5 m wall from Level 1 to the roof comes out as storey-high pieces, and each piece carries the whole wall's constraints. So the constraints are not used. A Revit brep with a cut top still gets no Height, and the method write-up gives the reason.

Result

On the 15 models, 3,159 of 3,247 measured walls now get a Height, up from 3,133. On the Schultz Residence (Revit 2014) the fill now leaves 5 of 105 walls failing instead of 14. The 5 left have no body that can be read. IfcTester 0.9.0 agrees on all 200 written values: each one failed before the fill and passes after it, and nothing else started failing. Method and per-model numbers: eval/wall-cut-top-heights-2026-11-22.md.

If you have a Tekla, Vectorworks or Allplan export that stores a clipped wall's Qto_ Height, that one file would tell us that tool's convention.

The checker gives estimates read from the model's geometry. It is not professional advice; check quantities that go into a contract.

All writing · More in Tools and projects · More on IDS Model Check · All tools and research