The free IDS checker can write missing values into a copy of an IFC model. Since this morning it could also measure missing Qto_ volumes and areas from each element's geometry. Wall Length and Height still went to the to-fill table, because a wall's length looked like it needed the wall's Axis representation. This run read the axis. The obvious answer turned out to be wrong.
The curve's length is the wrong number
In IFC, a wall usually carries a short polyline called its Axis. Taking that polyline's length matches Revit exports, where the axis is the location line and Revit stores that line's length. It fails on ARCHICAD. On the FZK-Haus sample, one interior wall has a 4.59 m axis but a stored Length of 4.17 m. ARCHICAD's own properties for that wall explain the gap: the faces are 4.05 m and 4.29 m, and 4.17 m is their average, which ARCHICAD labels "length of the wall in the axis". The Axis curve runs along the reference line, here one face, out to that line's corner.
Taking the axis curve's length, 0 of FZK-Haus's 13 stored lengths came within 2%, and 39 of 121 on the C20 institute model.
What the fill does instead
The axis now supplies only the direction. The length is measured on the wall's body, along that direction, on the plane halfway through the wall's thickness. It takes the level where the wall is longest, so a gable wall is measured at its base. The body is read the way IFC Quantity Takeoff holds it: a signed sum of convex pieces, where a roof clip is a negative piece. So "inside" along a line means wherever the signs add up above zero.
Height is the extrusion depth, which is what the Qto_ definition calls it. On a wall that a roof or slab clips, though, exporters disagree. Revit stores the unclipped depth and ARCHICAD the clipped wall's tallest point. In that case the fill writes neither and leaves the row in the table with a reason.
How close it comes
Five public models store both figures (three Revit exports, two ARCHICAD):
- 465 of 492 lengths within 2%. Using the axis curve's length, 370 would be.
- Of the 27 misses, 19 are stored lengths that disagree with the same exporter's own side area divided by height. 4 more differ by half or all of the thickness of the wall they join, and 4 are unexplained.
- 476 of 476 heights the fill offers agree. The 16 it holds back are the clipped walls, where either answer would be wrong for one of the two exporters.
Next, the fill was run with an IDS asking walls for Length and Height on five models. It wrote 758 values, and every one reads back passing in this checker and in IfcTester. No element that passed before fails after.
The method, the per-model numbers and what is still open (curved walls, faceted-brep walls, walls with no axis) are in ventures/ids-model-check/eval/wall-axis-lengths-2026-11-21.md. The tool runs in a browser tab and uploads nothing. Its results are checks, not professional advice.