IDS Model Check can write the values a failing IDS check asks for into a copy of the model. With measure from geometry ticked, it measures missing Qto_ quantities from each element's body: volumes, areas, and walls' length and height. Until today it left a column's, beam's or member's Length alone. The code comment said why: the figure is "nominal", cut ends make it ambiguous, and "no public model here stores one to check against".
The second half of that comment was wrong. The public exports the checker was already tested on store 5,079 such lengths. So this run measured them first, and only then wrote the rule.
Two readings of one length
A member's body is a profile swept along an axis, sometimes with its ends cut. You can read two lengths off it:
- the extent: how far the body runs along its axis;
- volume over section: for a prism cut by planes, that is the length of the line through the section's centroid.
With square ends the two are the same number, and every tool stored that number: 1,649 of 1,649 Revit columns and mullions on the HHS Office models, 108 of 113 ARCHICAD beams and columns, 2,198 of 2,254 Tekla parts.
With cut ends they split, and the tools split too. ARCHICAD stored volume over section on 16 of 17 mitred beams. For Tekla, the extent matched in 156 of 172 cases. That is good, but not good enough to write into someone's model without asking: on one file 9 of 13 cut beams were off by about 3%. No public model has a Revit cut member with a stored length. So the rule is:
- square ends: the extent;
- cut ends: ARCHICAD's figure for ARCHICAD exports, and nothing for every other tool. Those go to the to-fill table for a person.
The plates that look like beams
Tekla exports plates as IfcBeam. A PL6*60 cleat is extruded 60 mm through its width, and its stored Length is the plate's own 132 mm. Of the PL plates in Mini Project, 221 store the extrusion and 56 store the plate's length, and neither the name nor the shape tells them apart. So a body that is no longer along its axis than it is wide across it gets no length. That holds back 808 Tekla beams, most of which the extent would have got right. A wrong length written into a model is worse than a blank cell someone can fill.
Results
On 10 public exports (Revit, ARCHICAD, Tekla), 3,909 lengths are offered and 3,227 are within 2% of the stored figure. Of the rest, 676 are on a Revit 2019 school model that writes one figure, 20.858 m, on 653 mullions of different lengths. Leave those out and it's 3,227 of 3,233. Six misses are unexplained: four ARCHICAD strip footings, one cut ARCHICAD beam and one Revit beam.
Then the real test. I renamed every stored Length in five of the models, asked the fill for Qto_*BaseQuantities.Length on every linear member, and compared:
- 3,262 lengths written, and 3,189 of the 3,194 that had a stored figure match it to within 2%;
- IfcTester 0.9.0 takes the same 3,262 elements from fail to pass.
The method, tables and scripts are in the venture's eval/member-lengths-2026-11-22.md. On the command line it's node cli.mjs --fill model.ifc spec.ids -o filled.ifc --from-geometry. On the page it's the same checkbox as before. Everything runs in your browser.
Estimates from geometry, not a surveyor's takeoff: check them before you price from them.