FF/FL floor flatness calculator
For finishers, flatwork foremen, slab subcontractors and the general contractors who hold their retainage. A warehouse, a cold store or a floor under racking often comes with a spec like "FF 35 / FL 25 overall, 24 / 17 minimum local", and the number arrives a day or two after the pour from a testing agency. Running your own readings through the same arithmetic tells you before that report whether the finishing crew's method is working, which bays are dragging the number down and roughly how much grinding a miss would take.
Both come from elevations read every 12 inches along straight sample lines (ASTM E1155 is the US method).
q = (z₃ − z₂) − (z₂ − z₁). Bumps, trowel ridges and dips push it down.d = z₁₁ − z₁. A sag between columns or a slab that runs downhill pushes it down. A floor sloped on purpose for drainage is not tested for FL.Each number is a constant divided by "three standard deviations plus the absolute mean" of those values, all in inches:
FF = 4.57 / (3 × S_q + |mean q|) FL = 12.5 / (3 × S_d + |mean d|)
So the scale is linear: halve every bump and FF doubles. These are the equations given by the published secondary sources we could check; the standard itself is sold by ASTM, so check against your copy for contract work.
Thirteen readings, 12 inches apart, in inches above a datum (made-up numbers, chosen to be easy to follow):
0.00 0.04 0.06 0.04 0.00 -0.02 0.00 0.05 0.08 0.06 0.03 0.02 0.04
The 12-inch steps are +0.04, +0.02, −0.02, −0.04, −0.02, +0.02, +0.05, +0.03, −0.02, −0.03, −0.01, +0.02. Each curvature is the change from one step to the next:
| q values (in) | count | mean | standard deviation |
|---|---|---|---|
| −0.02 −0.04 −0.02 +0.02 +0.04 +0.03 −0.02 −0.05 −0.01 +0.02 +0.03 | 11 | −0.0018 | 0.0309 |
FF = 4.57 / (3 × 0.0309 + 0.0018) = 4.57 / 0.0946 = 48.3
Thirteen readings give three 10-ft differences (+0.03, −0.02, −0.02), far too few for a meaningful FL; the calculator says so instead of printing a number you might quote. A real test section pools many lines, hundreds of curvatures, read in two directions.
Paste those thirteen numbers into the calculator in "Sample lines" format and it returns FF 48.3. One of its tests repeats this hand calculation.
## Bay 3, area 2400; each section pools its own lines, and the overall number is area-weighted.Yes. FF is a constant divided by the spread of the curvature values, so halving every bump doubles FF. The same holds for FL and the 10-ft differences.
Far more than one line. A line under 11 readings gives no FL at all, and a handful of values swings widely. A real test section pools many lines read in two directions, hundreds of curvatures; the calculator flags samples under 30 values.
No. Use it to check your own work before the test or to read raw data a second way. When the contract names a testing agency, their E1155 report governs acceptance.