Paste your survey readings, a 12-inch elevation grid or a laser-scan point cloud. Get the floor's FF flatness and FL levelness numbers by section, pass or fail against your spec, the gap under a 10 ft straightedge, a heat map of the high and low spots, and an estimate of how much grinding would lift FF to the target. How F-numbers work, with a worked example.
1. Readings
2. Specification
From the contract. E1155 only measures; the limits are yours. Leave a box blank to skip it.
3. Results
Load the example or paste readings, then press the button.
Heat map
Elevation against the section's mean, one cell per reading. Black dots: readings the grind estimate lowers. Click a cell to see its row's profile.
mean
Profile
Sample lines
FF and FL of each line on its own, for finding the bad ones. Pass or fail is judged on the pooled section, not per line.
Line
Readings
FF
FL
Worst gap (in)
Questions
What are FF and FL?
FF (flatness) measures how bumpy a floor is over short distances, from the change in slope between readings 12 inches apart. FL (levelness) measures how far the floor wanders from level over 10 feet. Higher is better for both, and the scale is linear: a floor with FF 50 is about twice as flat as one with FF 25. ASTM E1155 is the US test method that defines them.
What readings do I need?
Elevations every 12 inches along straight sample lines, from a dipstick-type profiler, a laser level and rod, a total station or a robotic profiler, or a point cloud from a laser scanner. For FL a line needs at least 11 consecutive readings (10 feet). The tool pools every line in a section, as the method does.
How is the overall F-number for several sections worked out?
Each section's FF and FL come from all its readings pooled. The overall value for the floor is the area-weighted mean of the section values, the reading of ASTM E1155 section 9.15 that secondary copies of the standard give. Check it against your own copy of the standard before a contract result rests on it.
Is the grind estimate a grind plan?
No. It lowers the readings that stand highest above their neighbours until the section's FF reaches your target, and reports how many readings that took and how deep. It sees the floor only every 12 inches, cannot add material, and ignores what grinding does to wear surfaces, hardeners or embedded items. Use it to judge whether remediation is a small or a large job, then plan it with the flooring contractor.
Is my data uploaded?
No. The file is read and every calculation runs in your browser. Nothing is sent anywhere. An optional anonymous counter in this browser's local storage records only which features were used and the day.