FOR CONCRETE CONTRACTORS, QC TECHNICIANS AND SITE ENGINEERS
How strong is that slab right now?
Drop in your temperature logger's export and the lab breaks for the mix. The page fits the mix's strength-maturity curve, then shows each sensor's estimated in-place strength and when it should reach your form-stripping or stressing target, using the maturity method described in ASTM C1074. Everything runs in your browser.
A CSV with a date/time (or elapsed hours) column and one column per sensor. Most logger apps export this. Humidity, battery and index columns are ignored.
2. Maturity function
The datum and activation energy depend on the cement and admixtures. The defaults are commonly used starting values for plain portland cement; ASTM C1074's annex describes how to measure them for your mix.
3. Lab breaks for this mix
One specimen per line: age in days and strength. Two or more at each of several ages is best.
4. Target
Estimated in-place strength
Load a record and lab breaks, or try the made-up example.
Strength over time
Strength-maturity fit
Curve
R²
RMSE
AICc
Questions
What is the concrete maturity method?
Concrete gains strength faster when it is warm and slower when it is cold. The maturity method turns a temperature record into a single number, the maturity index, that accounts for both time and temperature. Once you know how strength rises with maturity for one mix (from lab cylinders broken at several ages), a sensor's maturity tells you roughly how strong the concrete around it is now. ASTM C1074 is the US standard practice that describes it.
What is the difference between Nurse-Saul and equivalent age?
Nurse-Saul adds up degrees above a datum temperature times hours (a temperature-time factor in degree-hours). Equivalent age converts each hour into the number of hours at a reference temperature that would have produced the same strength gain, using the Arrhenius equation and an activation energy. Equivalent age tracks the real temperature dependence better over a wide range; Nurse-Saul is simpler and widely used in the field.
What calibration data do I need?
Compressive strengths of specimens of the same mix, broken at several ages (commonly 1, 3, 7, 14 and 28 days, two or more at each), together with their maturity at the time of testing. If the specimens were moist-cured at a known constant temperature, the age is enough and the tool works out the maturity. If a logger sat in a companion specimen, enter the logged maturity directly.
Can I strip forms on this estimate alone?
No. The estimate assumes the field concrete is the same mix as the calibration specimens and was kept moist enough to keep hydrating. It cannot see a batching error, a wrong mix or a dried-out surface. ASTM C1074 itself asks for the estimate to be checked by other tests before critical operations. The engineer of record decides what evidence is needed.
Is my data uploaded?
No. The file is read and every calculation runs in your browser. Nothing is sent anywhere. An optional anonymous counter in this browser's local storage records only which features were used and the day.