The heavy-hydraulics programme asks whether a small excavator should carry a load-sensing pump or a cheaper fixed gear pump on an open-centre valve. Part of the answer is a selection rule: given a gear pump's catalogue curves, how good does it have to be before it beats the load-sensing pump on fuel? Earlier steps built a "pick table" for that rule, keyed on how steeply a pump's idle drag rises between 64 and 79 L/min (its bend).
Today's step (milestone 7zc) tested a change the previous step had recommended: key the table on the bend relative to the valve, r = b / b0, where b0 is the bend a pump with no drag at all would show on that valve. That number turned out to be the right way to say which pump families bend. We wrote four predictions down before running anything.
The key change made the table worse
Scored the same way as before (each idle condition and each pump maker left out of the fit, 308 held-out cases):
| Table key | Left-out RMS error |
|---|---|
| bend at the central setting (the existing table) | 0.0052 |
| relative bend r, mapped to a central-equivalent row | 0.0057 |
| the same, with rows built at r exactly | 0.0060 |
| raw bend at the machine's own valve curve | 0.0050 |
One prediction of four held. The reason is simple once you see it. The table's rows are built from pumps bent at the central setting, so a row needs to know how steep a pump's idle curve really is in kilowatts. Dividing by b0 sends twelve of fourteen pump variants to the flattest row on the steeper valve readings, and that row charges too little drag. The recommendation from 7zb was wrong, and the paper's supplement now says so.
The bigger find: half idle speed was never half speed for the gear pump
The previous step's half-speed bends did not match the factorial's half-speed bends for the same pump (Casappa KP30: 1.566 against 1.364), so we checked why. The factorial that every rule since milestone 7h was scored on builds each gear pump once, at working speed (2100 r/min). At "half idle speed" it slows the valve's neutral pressure and the load-sensing pump's standby flow, but it reads the gear pump's absorbed power off its 2100 r/min curves.
Read off its own 1050 r/min curves instead, a gear pump absorbs 0.31 to 0.66 of that idle power at 85 L/min on the PVG 32 valve reading, and 0.16 to 0.79 on the other two (leaving out Argo-Hytos GP3, whose datasheet lines carry no drag and go slightly negative at low speed). Danfoss is the least reduced, because most of its drag at that speed does not fall with speed. So the half-speed results in the paper (that idling at half speed raises the efficiency a gear pump needs by 0.02 to 0.03, and that a rule frozen at working speed misses there by up to 0.035) describe a machine whose gear pump keeps spinning at full speed while the engine idles. Corrected, the gear pump's idle penalty shrinks much more than the competitor's, so we expect the half-speed crossing to fall, not rise. That is a prediction for the next step, not a result.
The working-speed conditions, the central setting and every excavator break-even at working speed are unaffected. The manuscript now says this in its limitations, citing the diagnostic's output (experiments/gear_pump_halfspeed_results.txt). The next milestone rebuilds the 22-condition factorial with each pump at its own idle speed.
Reproduce
cd research/heavy-hydraulics/experiments
python gear_pump_halfspeed.py # seconds, no downloads
python gear_pump_bendtable.py # ~15 min first time: rebuilds caches from Hugging Face
python gear_pump_rkey.py # ~2.5 min on the cache
Everything is in LOG.md, "Milestone 7zc".