A gear pump catalogue that only draws curves near rated pressure can't tell you its idle drag

Cut seven gear-pump catalogues to their top 50 bar of power curves: idle drag moves a median 30% and three of seven families flip from flat to steep or back.

The heavy-hydraulics programme asks which fixed gear pump gets a small excavator closest to load-sensing fuel use. A lot depends on how much power the pump draws while the machine idles, and on how fast that idle drag rises as you pick a bigger pump (we call this its bend). One measured family, Danfoss's GearMe Group 3, bends much harder than the other six (1.78 against 1.29 to 1.37 between a 64 and a 79 L/min pump). Every result since then has been waiting on a second family that bends like it.

So today we went looking for one. Of the catalogues we could download, Danfoss's other GearMe groups are too small or have no curves, and Parker's PGP lists input power at one pressure only. One catalogue was in range: Magister Hydraulics' GP3K, 20 to 90 cm³/rev. But it draws input power only within about 50 bar of each size's maximum pressure (250 to 300 bar on the small sizes). To get idle drag from that you have to extend a straight line 150 to 250 bar down to near zero.

We checked how badly that goes on the seven families where we already know the answer. Each catalogue was cut to the same top band, and the model computed the idle drag again (catalogue_screen.py):

FamilyIdle drag at 64 L/min, full → top bandBend, full → top band
Casappa KP302.37 → 3.87 kW1.37 → 1.28
Danfoss SNP32.42 → 1.71 kW1.78 → −0.01
Marzocchi ALP32.49 → 2.57 kW1.30 → 1.21
Rexroth AZPG1.77 → 0.07 kW1.31 → 5.91
Rexroth AZPU1.69 → 0.65 kW1.34 → 2.62
Rexroth AZPN1.78 → 1.55 kW1.28 → 1.20
Rexroth AZPF1.84 → 1.49 kW1.30 → 1.31

The idle drag moves by a median of 30%, and by up to 96%. Three of the seven families change class: the one family we know bends reads as flat (with a negative absorbed power at 79 L/min), and two flat ones read as bending harder than Danfoss. Three of our four predictions about this, written down before the run, held.

What this means: a catalogue drawn this way can't be the second bending family, so the search now needs a catalogue that draws a 50 or 100 bar curve, or bench data. If you are comparing gear pumps on idle losses yourself, you have the same problem. Power curves drawn only near rated pressure tell you nothing about what the pump burns at idle.

Caveats: the band width (50 bar) is taken from one catalogue, we left the flow lines as drawn so the test only measures the drag error, and we didn't open every manufacturer's catalogue. The full numbers and the screen are in the project's research log under milestone 7y.

All writing · More in Research findings · All tools and research