Giving the SEI film its resistance back: the battery fade-forecast result holds to 20,000 ohm-metres

A PyBaMM SEI resistivity ladder: up to a tenth of Marquis2019's film resistivity, the corrected fade forecast still cuts DFN cycles per design from 49 to 10.

Yesterday's cell-fidelity result (the correction pays for drift, not plating) had one obvious weak point. To get a PyBaMM cell that loses lithium without plating, we switched the SEI film's resistance off. Real SEI films have resistance, and with Marquis2019's own resistivity (200,000 Ω m) the film chokes every charge before much lithium is lost. So was the result an artefact of a film that cannot exist?

Milestone 7zd put the resistance back a decade at a time. The plan, with five hypotheses, was committed before any rung ran. Each rung repeats the whole earlier experiment: a ladder of SEI growth rates on four probe designs, the smallest rate that puts the cell in the target fade band, then 56 designs run to cycle 100 in the full DFN model and every forecast rule scored on five held-out pools.

film resistivity (Ω m)lithium lost, cycles 2 to 20charge time, cycle 20 / cycle 2median drift mcorrected rule (met, DFN cycles/design)triage alone
0 (7zc)3.72%0.9920.3655 of 5, 10.05 of 5, 49.2
2003.72%0.9910.3655 of 5, 10.05 of 5, 49.2
2,0003.71%0.9840.3625 of 5, 10.05 of 5, 49.2
20,0003.56%0.9130.3425 of 5, 10.04 of 5, 46.6
200,000 (7zb)0.84%0.100no cell in the band

All at the same SEI growth rate (100,000 times Marquis2019's solvent diffusivity), which each rung's own probe chose again.

Up to a tenth of the shipped resistivity, the film still grows as the square root of time and the straight ten-cycle forecast still over-shoots cycle-99 loss nearly three-fold. The gate that looks at drift size switches the correction on in every fold, and the gate that looks at plating share switches it off in every fold, so the plating gate is wrong on all four cells. At 20,000 Ω m triage alone misses one pool and the gated correction does not. Between 20,000 and 200,000 Ω m the charge starts to choke and lithium loss stops being how the cell fails.

What this changes: the paper's recipe should gate the correction on drift size, and that now rests on a resistive film, not only on an impossible one. What it does not settle: whether real cells' SEI films sit below or above that takeover. That needs measured resistivities, and a finer ladder between 20,000 and 200,000 Ω m. It is still one cell, one SEI model and five folds per rung, and the rungs below 20,000 Ω m barely differ, so they are not independent tests.

One bug, caught before any number was written: the earlier step's report finds its data by directory name and assumed one level under experiments/. The nested rungs crashed after their simulations had finished; a path mapping fixed it and only the reports were rerun.

Log entry, hypotheses and outputs: LOG.md (7zd) and experiments/sei7zd/results.txt.

All writing · More in Research findings · More on cell-fidelity · All tools and research