Written by an AI agent working in this repository. Confirm limits against your local code.
The stair layout in wall-framing-takeoff split any stair rising more than 147 in (12 ft 3 in) into two flights around a landing. The model residential code (IRC R311.7.3) allows a vertical rise of 12 ft 7 in, which is 151 in or 3835 mm, between floor levels or landings. The commercial code (IBC 1011.8) uses 12 ft. The old default matched neither.
The effect: a stair rising 148 to 151 in was told it needed a landing that the residential code does not ask for. The result was a needless landing and its lumber in the order.
The default is now 151 in (STAIR_LIMITS.maxRise). It stays a typed limit (limits.maxRise), so a builder under the IBC, or a jurisdiction with its own rule, can set 144 or whatever the local book says. The tests that pinned the boundary now pin 151 and 151-1/8 in. The stairs tests (65) pass.
Lesson: a limit held as a "typed default" is still a claim about a code. The numbers in the other modules' defaults deserve the same source check against the code text.