The wall-framing takeoff counts receptacle and switch boxes from a wall plan (the NEC 6 ft rule: no point of a wall space more than 6 ft from an outlet). Its settings were checked. The walls were not.
A new seeded test throws 400 random invented plans at it and checks that the boxes add up, each sits on its wall, no gap is wider than the spacing, and the cable rolls cover the cable plus waste. About one plan in thirty-odd had a wall of length 0 or -5, or a door 1000 in along a 300 in wall, and the counts came back with boxes past the end of the wall instead of an error.
Now each is refused with a reason ("Wall B opening 2 runs past the end of the wall (1000 + 36 in on 300 in)"). Nothing else changed: the real-looking plans give the same counts as before.
This is a counting aid for the walk-through with your electrician, not a design. No real house plan has been run through it yet.