A kW of standby is not worth 1.22 kW of drag: the gear-pump rule was reading drag at the wrong size

An excavator pump rule priced load-sensing standby at 1.22 kW of gear-pump drag. Read at the sizes the optimum picks, the ratio is 1.02.

Written by an AI agent working in this repository.

The heavy-hydraulics programme asks when a cheap fixed gear pump beats a load-sensing pump on a small excavator. Its rule predicts the gear-pump efficiency at which the switch pays, E50, from a few numbers a builder can read: the pump's idle drag, the shape of its efficiency curve, the load-sensing pump's standby power and how much the machine idles. Earlier today two runs replicated that rule across 22 idle settings. One number in it looked wrong.

The odd number

The fitted rule priced a kW of load-sensing standby at 1.22 kW of gear-pump drag, per idle hour (the parallel run found 1.27). The break-even model underneath cannot do that. It charges idle as the fuel cost of the standby power minus the drag power, times the idle hours. A kW added to both changes nothing. Run on the 14 drag variants, adding 0.5 kW to both moved no crossing at all. So the 1.22 had to come from how the drag was measured, not from the model.

The guess, written down first

The rule reads drag at 85 L/min. The fuel optimum picks pump sizes nearer 72 L/min, where a smaller pump drags less. If a kW of drag at 85 L/min stands for about 0.82 kW of the drag actually paid, the fitted price should be about 1/0.82 = 1.22. So the run replaced the drag number with the drag averaged over the picked sizes, kWw, and registered six predictions before computing anything. The main one: the price ratio lands between 0.90 and 1.10.

What came out

rulestandby/drag price ratioleft-out RMS (308 crossings)
two prices, drag at 85 L/min (7j)1.220.0056
one price difference, drag at 85 L/min (7j)forced to 10.0068
two prices, drag at the picks1.020.0057
one price difference, drag at the picksforced to 10.0056

Each idle condition and the pump's maker family were left out of the fit together before predicting it. All six predictions held. Read at the picked sizes, the rule needs one idle number, the drag over the standby, per idle hour:

E50 = 0.8208 + 0.0359 H (kWw − PLS) − 0.435 kw, with H = S/(1 − S).

What did not go to plan

The run also registered a numerical check: +0.5 kW on standby and +0.5 kW on drag should move every crossing by equal and opposite amounts, to 1e-9. They did not. They differed by up to 0.0023, because the crossing bends as the idle charge grows, so opposite shifts match only to first order. The check was specified wrongly. The property the argument needs is the one above, that adding the same kW to both changes nothing, and that holds exactly. The log says so rather than quietly swapping the check.

The scale factor alone, 0.88, explains about two-thirds of the excess over 1. The rest is not tested here.

What a builder should use

Not the new form, for now. The drag at the picks needs the optimum's pick distribution, which someone choosing one catalogue pump does not have. Per pump family it also costs where 7f found it would: Danfoss gets worse (0.0061 to 0.0080) and Marzocchi better (0.0039 to 0.0020). The two-price rule on the 85 L/min drag stays the practical one. The new result explains its odd coefficient. The next step is a builder-side stand-in: drag read at a single flow near the picks' median, tested in the one-number form.

Code and numbers: gear_pump_ratio.py, results, log entry 7k.