Tennis robots: the feeder's levelling feet could not level, and their studs bent in the wind

A levelling foot screwed into a T-nut has 4 mm of travel. Drawn as a joint, the feeder's feet also bent in the design wind. A printed block fixes both.

The open tennis robots' ball feeder stands behind a 3 m net beam. Four wheels carry it, and two levelling feet under the beam's ends stop it rocking when the net catches wind. Until today the CAD drew each foot as a 40 by 155 mm cylinder. The parts list said: an M6 levelling foot with 155 mm of stud, screwed into a T-nut in the beam's bottom slot, locked with a jam nut.

Every other nut on the feeder is a checked joint: the build measures what it clamps, checks the thread past it and swings a spanner and a hand round it. The jam nuts were the last ones left. To check them, the foot had to be drawn as it is, a pad and a stud. Drawn that way, the mount failed four ways.

It cannot level. A stud screwed up into a T-nut has to sit between catching the nut's threads and hitting the slot's floor. The window the build uses for T-nut screws is 4 to 8 mm past the beam's face, so the foot has 4 mm of travel in all. A court falls and crowns over the 2.9 m between the feet, and the tyres squash. We assumed 12 mm either way is needed.

The listed stud did not fit. On a 25 mm pad (assumed), 155 mm of stud puts the tip 180 mm off the ground. The beam's face is at 155 mm, so the tip would run 25 mm past it, 17 mm past the slot's floor.

The stud bends. A swivel pad's ball joint carries no moment, so the bare stud between the pad and the beam is a cantilever. The wheels are not braked, so in the worst case the two feet take all of the design wind's 69 N on the net. Half of that, at the end of 142 mm of M6 (with the ground 12 mm lower), is 4.9 N m on a 4.77 mm core. That is 460 MPa. A typical class 4.8 stud yields at 320.

The spanner was wrong. The step asked for a 13 mm spanner. An M6 nut is 10 mm across the flats.

The fix

Each beam end now gets a printed foot block. A 6 mm flange screws up into the bottom slot with two M5 x 12 into T-nuts, which puts the screws 6 mm past the face, the middle of the window. A 20 by 24 mm column runs down to 55 mm off the ground. An M6 nut slides into a slot low in the column from the rear and sits on a 5 mm wall. The foot's stud, now a stock M6 x 80, screws up through the nut into a bore that runs up to the beam. The jam nut locks it under the column.

Stud into a T-nutFoot block
Pad travel from level4 mm in all50 mm up, 38 mm down
Bare stud, worst case142 mm42 mm
Stud bending at design wind460 MPa, 0.70x yield136 MPa, 2.35x yield
Spanner13 mm (wrong)10 mm

The column carries the moment up to the flange at 3.0 MPa. That is under the 10 MPa we allow for printed PETG. The flange tips about its edge, 10 mm from the screws, so each T-nut takes a 235 N pull. We allow 500 N, an assumption to check against a supplier's sheet.

Both are joints now, 41 on the feeder. The block's screws are checked against the T-nut window, and their heads can be reached with the key from below, past the column. The jam nut's stack is the column's 5 mm wall, and there are 30 mm of stud below it. A 10 mm spanner and the hand holding it turn all the way round at both feet. With the ground 12 mm higher, there are still 14.8 mm of stud between the pad and the block, so the jam nut always has room for a spanner. Each check has a test that makes it fire on a bad value.

What is assumed

Nothing here has been built. The pad's height, the stud's grade, the share of the wind each foot takes, a T-nut's allowed pull and how far a court falls between the feet are all assumptions. PETG creeps under steady load. The feet are set just off the ground, so they carry little until the wind blows. The full write-up is in the venture's CAD README, under "Levelling feet".