Revit's door sizes come from the family, not the hole in the wall

The free IDS checker now fills missing door and window Width, Height and Area on Revit IFC exports: 796 of 800 stored figures matched to the last digit.

When an information delivery specification (IDS) asks every door in a model for Qto_DoorBaseQuantities.Width, Height and Area, and the model doesn't have them, IDS Model Check can write them in. Until today it did that only for ARCHICAD exports. ARCHICAD measures the opening a door fills, and we could reproduce its figures to the last digit. Revit exports got nothing, because the three public Revit models we test against seemed to disagree with each other and with the opening:

  • a Revit 2022 door stored a 2.05 m height inside a 2.15 m opening;
  • a Revit 2019 door stored 0.99 m wide in a 1.01 m opening;
  • a Revit 2010 door matched its OverallWidth attribute most of the time.

No single geometric rule fitted all three, so the earlier run held back rather than write wrong figures.

Reading the exporter instead of guessing

Autodesk publishes the Revit IFC exporter's source on GitHub. Its calculators answer the question directly. For a door or window:

  • Width is the family's Width parameter, taken from the instance if it has one and otherwise from the type.
  • Height is the family's Height parameter, looked up the same way.
  • Area is width times height, and has been since at least 2018.
  • Perimeter is the outer outline of the extruded body, so it comes from the geometry, not from the parameters.

So none of these figures is measured from the opening. They are what the designer typed into the family. A German family's height can be the leaf's nominal 2.05 m even though the wall opening is 2.15 m. That explains the 2022 file, and nothing in the geometry would have told us.

A Revit export carries those parameters as ordinary properties, grouped by parameter group: Dimensions(Type) in English, Bemaßungen in German, and PSet_Revit_Type_Dimensions in 2010's naming. So the checker can read them back.

How well it matches

On all three public Revit exports, against every figure Revit itself stored:

ExportWidths exactHeights exactAreas exact
Revit 2010 (office, 133 doors)129 of 133129 of 133none stored
Revit 2019 (school, 568 doors and windows)568 of 568568 of 568IFC2x3: not offered
Revit 2022 (flat, 99 doors and windows)99 of 9999 of 9999 of 99

The four misses are the same four steel-framed doors in the 2010 model. Revit stored the frame's outer size for those, about 49 mm wider than the nominal 885 mm. No exported property carries that figure, so the checker writes the nominal size, which is 5% under. We know of no other way the rule goes wrong.

We also tested the fill end to end. We hid the stored figures, asked for them back, and then checked the result with IfcTester, buildingSMART's reference checker. Every door and window in the 2022 flat went from failing to passing on Width, Height and Area, and every door in the 2010 office went from failing to passing on Width and Height.

What it still won't do

  • Perimeter on Revit models. Revit's figure comes from the body's outline, and none of the public exports stores one we could check against, so that request stays in the to-fill table.
  • Area on IFC2x3 Revit exports. The 2019 model's older BaseQuantities set stores an area that isn't width times height on any of its 576 doors and windows.
  • Parameter-group names in other languages, such as French or Norwegian. We will add them when a public export in that language turns up to check them against.

The full method, the scripts and every number are in the venture's eval/revit-door-window-quantities-2026-11-22.md. The checker runs in your browser, and the model never leaves your machine.