An infinite wall volume read as a unit slip: red team on an IFC quantity takeoff

Red team on an IFC quantity takeoff: 11 of 20 seeded bugs caught, 9 gaps closed, and a stored 1.E400 volume no longer reads as a unit slip.

Today's red-team run went at the IFC quantity takeoff, which reads a BIM model in the browser and turns it into a bill of quantities. It checks every quantity the model stores against the geometry and names the reason when the two disagree. Two files were the targets: qto.mjs (the takeoff and its explanations) and geom.mjs (profiles, curves, booleans and the triangulator). Their 270 tests run in about three seconds.

We tried the playoff-race solver in the league schedule generator first. Its whole suite takes minutes, which is too long to run once per mutant, so that campaign was stopped. A differential fuzz did run against it: 3,000 random small leagues, with six point systems, compared against full enumeration and then rerun at budgets from 1 to 30 nodes. Clinch, elimination and magic numbers matched every time, and with the budget cut short they always stayed on the safe side.

Seeded bugs

FileSeededCaughtGaps closed
ifc-quantity-takeoff/qto.mjs1064
ifc-quantity-takeoff/geom.mjs1055

Catch rate went from 11 of 20 to 20 of 20 after the new tests. These got through:

  • The glass test's transparency < 1 changed to < 2. A surface style drawn fully transparent is air or a void, not a pane, but no test had a style at exactly 1. One does now, plus one at 0.99 that still counts.
  • A room's placement made enumerable. That would have leaked the room's world matrix into the JSON and CSV output. A test now checks that the solid, placement and unit stay hidden.
  • A footprint room's box corner read from the wrong argument. Rooms built from a FootPrint curve and a bounding box would all start at z = 0. The new test raises the box corner by 300 mm and checks that the room moves up with it.
  • computed > 0 changed to computed > 1 in the compound unit-slip check. Every fixture had a volume over 1 m³, so a 0.4 m³ slab never came up.
  • Five geometry faults: a parameter-trimmed line divided by its parameter instead of multiplied, the three-point arc's determinant, a T profile's flange corner, the bounded half space's axis taken from the translation column, and the ear clipper's point-in-triangle test turned into an or. The ear clipper passed the old L-shaped test and failed only on a comb with three teeth. Each fault now has a test written for it.

The real defect

unitSlip checks whether a stored figure is the computed one times 10ⁿ or times 10.7639 (square feet). Its comparison is |a − b| <= tol × |b|. When the stored value is Infinity, both sides are Infinity, so the check passed for any factor. A STEP file that stores GrossVolume 1.E400 parses to Infinity, and the 3 m³ wall in our sample model came back as "unit slip, factor 10.7639". Both slip checks now take finite numbers only. The same wall now gets the explanation that holds: the stored volume disagrees with the wall's own stored dimensions, and the geometry agrees with them.

It is a small bug. But the product's selling point is that each explanation it gives can be trusted, so a made-up explanation is worse than "unexplained".