Quality fix: our CMMC score counted a requirement as met when one of its objectives was not

Under 32 CFR 170.24, a CMMC requirement is NOT MET if any assessment objective is not satisfied. CMMC Workspace now scores it that way and flags it.

The SPRS score is 110 minus the point value of every NIST SP 800-171 requirement you have not met. Each requirement has one or more assessment objectives in NIST SP 800-171A, 320 in all. The CMMC rule decides how the two fit together. 32 CFR 170.24(b)(2) says a requirement is Not Met when "one or more applicable objectives for the security requirement is not satisfied". We read the rule on eCFR on 2026-11-27.

The quality audit of 2026-11-26 (audit file, defect 0) found that CMMC Workspace did not apply this rule. The app records two things for each requirement: its status (implemented, partially implemented and so on) and a met or not-met result for each objective. The score read only the status. So if you marked AC.L2-3.1.1 implemented and one of its six objectives not met, the score still gave you all 5 points. That is the number your affirming official types into SPRS, and it was too high with no warning. Our own FAQ page already said "a requirement counts as met only when every one of its NIST SP 800-171A assessment objectives is met". The app did not follow it.

What changed

  • The score reads the objectives. A requirement counts as met only when its status is implemented or not applicable and none of its objectives is recorded as not met. In the case above, the score is now 105, not 110. Level 1 works the same way: one objective not met fails that requirement, and so the whole level.
  • The conflict is shown, not just scored. The dashboard now lists each requirement whose status says met while an objective says not met. The generated System Security Plan says the same in its self-assessment summary. You can then fix the status or re-assess the objective before the score goes to SPRS.
  • The SSP rule follows the objectives too. If an objective of 3.12.4 (the system security plan) is not met, the app now produces no score. The methodology produces none without an SSP.
  • Citations corrected. The POA&M reasons cited 32 CFR 170.21(a)(2)(iii) for the 1-point rule and (a)(2)(iv) for the six requirements that can never be on a POA&M. The rule numbers them (a)(2)(ii) and (a)(2)(iii), and there is no (a)(2)(iv). Defect 3 in the same audit. The free SPRS score calculator carried the same wrong number and is corrected too.

Tests that would have caught it

The audit also found three POA&M checks with no test. A mutant could let a 3-point requirement such as 3.1.5 or 3.8.8 onto a Conditional-status POA&M, reject a score of exactly 88, or report "all 110 met" while gaps were open, and every test stayed green (defects 1 and 4). We added tests for all of these:

seeded changebeforenow
status alone decides met (objectives ignored)not tested4 tests fail
weight === 1 → weight <= 3 in POA&M eligibilitysurvived1 test fails
score < 88 → score <= 88survived1 test fails
allMet hard-wired to truesurvived3 tests fail

The unit suite has 508 tests and passes, and the typecheck is clean. The worker suite and the run record are in the pull request.

What is still open

The audit's defect 2 is still open. 32 CFR 170.24(b)(1)(i) and (ii) assess two more cases as MET: enduring exceptions described in the SSP, and temporary deficiencies under an operational plan of action. The app does not model either yet. A requirement under one of them has to be recorded as implemented, with the reason in its notes. A later audit will re-check all of this.

The re-check, 2026-11-28

A re-audit the next day (audit file) checked every defect from the first audit against the code as it now is. The four this fix marked are closed. The case above scores 105, lists the conflict, and blocks Conditional status, because 3.1.1 is worth 5 points and only 1-point requirements may be on the POA&M. All three mutants that used to survive now fail a test.

We redid the arithmetic by hand from the DoD Assessment Methodology and 32 CFR 170.21. Seven cases match:

caseby handapp
3.1.1 not met, 3.1.3 partial, 3.5.3 MFA for remote and privileged users only110 − 5 − 1 − 3 = 101101
3.13.11 encrypted, not FIPS-validated107, may be on the POA&M107, eligible
3.1.1 implemented, objective [a] not met105105, flagged
nothing implemented but the SSP−203−203
22 one-point items open, then 2388 passes, 87 does notsame
POA&M closeout from 2026-01-15 and from 2028-01-152026-07-14, 2028-07-13 (leap year)same

We also scored 2,000 random assessments with the app and with the free SPRS calculator. The two engines were written separately, and they gave the same score every time.

The re-audit found three small defects the fix had not touched, plus one new one. All four are fixed in the same pull request:

  • A result can now be cleared. Once an objective was marked met, not met or N/A, there was no way to set it back to unanswered. Choosing "—" now clears it.
  • The two Level 1 lists are now checked against each other. The app's list of the 15 Level 1 requirements was typed out a second time, apart from the list behind the free Level 1 checklist, and nothing kept the two the same. A new test checks every requirement and all 59 objectives. The wording matches word for word, but the test found one difference. Where NIST gives a requirement only one objective (3.10.4 and 3.14.4), the free page calls it "3.10.4" and the app calls it "3.10.4[a]". The test now pins that this is the only difference.
  • A new test for the conflict list. A requirement you already marked not implemented, with an objective not met, is consistent, and it should not appear in the conflict warning. Nothing tested that until now.

Re-audit result: the app now meets the bar on correctness, claims and tests. It still falls short on fitness, because of the gap above: operational plans of action and enduring exceptions. That is the next fix.

This is a planning aid, not a determination. Your affirming official makes the self-assessment and the affirmation in SPRS, and this is not legal advice.

All writing · More in Quality audits · All tools and research