The codesign-cant programme tunes a small quadrotor's gains with CMA-ES while randomising the plant. One randomised input is motor lag. Two published identifications of 5-inch quadrotors put it at 33 and 39.1 ms. Earlier steps found that the training range should start at the slow identification and run well past it. This morning's run found that a ceiling of 150 ms (3.8× the slow identification) beats 125 ms at ten seeds per geometry. Six seeds had hidden that gap.
The obvious next question was whether 200 ms (5.1×) beats 150 ms. At six seeds the pair gave 65 against 53 crashes over the identified lags, p = 0.16. Since six seeds had hidden the last gap, we ran the same experiment again. Seeds 6-9 of the 200 ms arm were trained in both centre-of-pressure geometries and scored on the same held-out stress set. The predictions were committed before the run.
What ten seeds show
The crash count covers flights that diverge at twice the trained centre-of-pressure lever and a 45° tilt limit, summed over the 33, 36 and 39.1 ms laws.
| 150 ms ceiling | 200 ms ceiling | |
|---|---|---|
| crashes at the identified lags (of 3,840) | 112 | 86 |
| crashes with a 75 ms motor (of 1,280) | 462 | 217 |
| median mass, centre of pressure above / below | 1.47 / 1.43 kg | 1.57 / 1.49 kg |
| median 1 m-step rise, above / below | 2.08 / 1.83 s | 2.21 / 2.27 s |
At the identified lags the two ceilings are not separated: pooled Mann-Whitney p = 0.08. Paired by geometry and seed, 150 ms crashes more in 13 of 20 pairs and ties in 4 (exact Wilcoxon p = 0.07). The point estimate is a 23% drop, so this is not proof that the extra coverage does nothing. It does mean that ten seeds per geometry cannot detect a gain, and any gain is a quarter or less. Compare 125 → 150 ms, which gave a 43% drop at p = 0.004 with the same number of seeds.
With a motor slower than either identification, the extra coverage clearly pays. At 75 ms, 200 ms crashes on fewer flights in all 20 pairs and less than half as often overall. It costs 4-7% more mass and a slower step response.
We had predicted (prior 40% and 50%) that the pair would separate, and it did not. Two other predictions failed as well. One was a floor of 2-4 crashes per design with the centre of pressure above: two of the ten designs fell outside it, at 1 and 6. The other result reversed a six-seed reading: 200 ms now rises slower than 150 ms in both geometries.
What a builder should take from it
Keep the training ceiling at about 4× the slowest identified motor lag. Go to 5× only if you think your motors may really be slower than the identification says, because that is where 200 ms earns its extra mass.
Everything here is simulated, scored on one held-out seed of 64 episodes per design and law. The paper draft, the stats script and the reproduction check (every re-scored seed-0-5 record matches its stored value) are in experiments/m12d_ten_seeds_c200.