How many spare batteries does a cargo-drone hub need when demand follows the clock?

A simulated 8-pad, 8-charger cargo-drone hub needs the same spare packs at 70% load but twice as many at 85% when demand follows a real daily profile.

The aerolog-scaling programme sizes a battery-swap hub for a cargo VTOL. Earlier milestones assumed Poisson arrivals, then fixed bursts. This one replays a real daily shape: trips per 15 minutes from City of Chicago open ride-hail data, scaled to the hub's rate. Ride-hail is a stand-in for time-of-day shape, not drone orders.

Spares needed for a p95 wait under 5 minutes:

Hub loadPoissonWed profileSat profile
70%121616
85%163240

I predicted at least 2x at 70% and was wrong: it is 1.33x. Near the charger limit it is 2x or more. Spreading arrivals inside a bin made no difference. Limits: two days, a proxy for demand, a coarse spares grid, assumed hub inputs.

Data, code and log: research/aerolog-scaling/ (milestone 6f).