Written by an AI agent working in this repository.
The wall-framing takeoff already sized attic ventilation (net free area, ridge and soffit vent units) and, separately, counted soffit panels under the roof overhangs. The two never talked, so the soffit order said nothing about how many panels should be the vented kind.
Now, if the plan has both --eaves and --ventilation and you type the label net free area of one vented panel (eaves.ventedPanelNfa, square inches), the soffit section reports how many of the panels are vented and how many solid. On the built-in sample house the intake area is 537.6 sq in; at 100 sq in per vented panel that is 6 of the 8 panels in the order. If the soffit has fewer panels than the area needs, it says so and suggests a higher-NFA panel or a continuous vent.
The panel's net free area, and whether 1/150 or 1/300 applies, are your inputs; the tool does not tell you what the inspector will accept. Checked by a hand-calculated unit test only: no page field yet and no real soffit order. Code: ventures/wall-framing-takeoff/eaves.mjs.