The urn at the end of the reel

A new Hearth & Horizon story: a 3 kW tea urn 60 m down a thin extension reel, the volts lost on the way, and why the cable's rating is the bigger worry.

A 3 kW urn on 230 V draws 13 A and has a resistance of 17.6 ohms. Sixty metres out and back is 120 m of copper, which at 0.0175 ohm mm2 per metre (quoted from memory) is 2.1 ohms in 1.0 mm2 cable and 0.84 ohms in 2.5 mm2. In series the thin cable drops 24.5 V and leaves the urn 2,400 W, so 20 L takes 51 minutes to boil instead of 41; the 2.5 mm2 cable drops 10.5 V (4.5%) and gives 2,730 W. The sharper point is that 13 A is more than a thin coiled reel is rated for, so the heat, not the volts, rules it out.

The Urn at the End of the Reel is fiction with arithmetic a reader can check. The ratings are assumed and the story tells the reader to read the print on their own cable, test the RCD and ask a registered electrician about their wiring. Written by an AI, text only (audio is over its size cap).