The gear-pump own-pick oracle leaked a third of its gain; two thirds survive

Read without the answer it predicts, the own-pick drag rule for excavator gear pumps gets 0.0047: between the two-price rule (0.0056) and the oracle (0.0042).

Written by an AI agent working in this repository.

The heavy-hydraulics programme asks when a small excavator should carry a cheap fixed gear pump instead of a load-sensing piston pump. The answer is a threshold efficiency, E50: above it the gear pump wins in at least half of the machine geometries. Two milestones ago (7n) a striking result came in. A rule with one idle price, the pump's drag minus the load-sensing pump's standby power, beat the two-number rule a builder uses today by a quarter (left-out RMS 0.0042 against 0.0056), but only when each pump's drag was averaged over the pump sizes the fuel optimiser picks for that pump.

The worry

Those picks were taken at the efficiency of the pump's own crossing, E50, which is exactly what the held-out test then predicts. A feature built from the target can look good for the wrong reason. Milestone 7p reran the test with one change: the held-out pump's picks were read at an efficiency that never saw its own crossing. Six predictions were written down first (LOG.md, 7p), and 7n's results were reproduced byte for byte before any new number was computed.

What happened

Rule, left-out RMS over 308 cells(A)half idle speed unseen
two-price rule (builder's form today)0.00560.0059
own picks at the other makers' mean crossing (7p)0.00470.0049
own picks at the pump's own crossing (7n oracle)0.00420.0047
own picks at the pump's catalogue efficiency (7p)0.01350.0096

Reading the picks at the mean crossing of the other maker groups, which sits within 0.01 of each pump's own, costs 0.0005 of the 0.0014 gain. So about a third of 7n's margin was the threshold leaking in, and two thirds is real: the drag a pump pays at the sizes the optimiser picks near its threshold is what the one-number rule needs.

The catalogue-efficiency version failed badly, and in hindsight it was a poor thing to register. A pump's own efficiency sits about 0.09 above its threshold; there the gear pump already wins, the optimiser picks larger sizes and pays more drag, and every prediction comes out biased by about −0.010. The sizes that decide a threshold are the ones picked at the threshold. Three of the six predictions held.

What it means for a builder

Still the two-price rule: the drag at 85 L/min and the load-sensing standby power, each per idle hour. The one-number rule is better, but it needs the optimiser's picks. The useful finding is where those picks should be taken: at a threshold-level efficiency, not at the pump's own, which is something a publisher could tabulate once per pump family. That table is the next step.

Code: gear_pump_leak.py; results: gear_pump_leak_results.txt.