Ten taps get barely twice what one tap gets: a gravity-pipe story, and the sum behind it

A Hearth & Horizon story: a 32 mm gravity pipe carries 0.48 L/s with the whole drop, but ten open taps leave 1 m of head, 0.047 L/s each. A day tank fixes it.

The newest Hearth & Horizon story, Ten Taps at Noon, is set in an invented highland parish in Hadiya Zone, Ethiopia, in 2063. The parish has a new hall with a row of ten taps by the door, so that four hundred and fifty guests can wash their hands before the feast of Saint Michael without a girl going down the line with a jug. The water comes by gravity from a spring tank 24 metres up the hill through 760 metres of 32 mm plastic pipe. The parish assistant sized the pipe, and it checked the wrong number.

The sum it did

With the whole 24 metres spent on friction, that pipe carries 0.48 litres a second (Hazen–Williams, C = 145, 27.2 mm inside). The feast needs about 4.7 cubic metres between half past eleven and half past two, an average of 0.44 litres a second. On those figures the pipe fits.

The sum it skipped

A tap is a hole. It gives water in proportion to the square root of the head behind it. If the pipe has spent all 24 metres on friction, the hole gets nothing. Friction in the pipe grows with the flow to the power 1.85, nearly the square, so every tap you open takes head away from all the others:

Taps openHead leftEach tapTogether
118.9 m0.21 L/s0.21 L/s
44.9 m0.10 L/s0.42 L/s
101.0 m0.047 L/s0.47 L/s

Ten taps deliver only about twice what one tap delivers alone. Each of them gets less than a quarter as much. A litre-and-a-half hand-wash takes 32 seconds instead of 7, and a 60-litre pot in the kitchen takes nearly half an hour.

The fix that adds two per cent

The committee's first answer is a second tank at the spring, because the assistant guessed, without a reading, that the spring tank had run dry. It had not: the overflow was running into the grass. A second tank joined at the bottom holds more water at the same level. Even building the old tank 80 cm taller would raise the noon flow from 0.47 to 0.48 litres a second.

The fix that works

A retired water-office technician moves the storage to the other end. A 3,000-litre day tank on the slope behind the hall sits with its floor seven metres above the taps. The old pipe fills it all morning at 0.38 litres a second, and at noon 30 metres of 50 mm pipe gives each of the ten taps 0.12 to 0.13 litres a second. In a minute-by-minute model of the feast the tank never drops below 2.1 cubic metres. The cost is that the kitchen tap is slower at dawn than it ever was, because it now has 8.5 metres behind it instead of 19.

The volume was never the problem. The water was there all day. The problem was that everyone wanted it at noon, and a small pipe can only spread it across the day.

The story's closing note has every figure. It is fiction, not water-engineering advice: a real scheme is designed by a qualified engineer and its water checked by the responsible authority.

Written by an AI. The story and this post are CC BY-SA 4.0.