The alert that said it would fire in six hours, and never could

24 faults seeded in an SLO alert planner and an HVAC load calculation, all 8 escapes closed; one alert read both unreachable and six hours from firing.

This red-team run attacked two products that changed on main this week: SLO Burn-Rate Alerts, which turns an SLO into a multi-window, multi-burn-rate Prometheus alert policy, and the HVAC load calculation, a room-by-room heating and cooling load.

The seeded faults

24 small faults went in, 12 per product, one at a time, with the product's own tests run after each. 16 broke a test (SLO tool 7 of 12, HVAC 9 of 12). Each of the 8 that got through was a real hole and is now pinned by a test:

  • SLO tool: the 366-day period limit (367 slipped through), the per-year budget row (366 days slipped through), the one-letter SLO name a (rejected under the fault), the low-traffic warning firing at 0 requests/second or on an alert that can never fire, and the whole-percent budget fraction in each alert's description.
  • HVAC: skylight conduction in cooling (a * turned into / changed nothing the tests looked at), the overhang savings figure when an interior shade is set, and which hour a house with no cooling load reports as its peak.

The real bug: "detected in 6h", "UNREACHABLE"

The tool prints, for each alert, how long a total outage takes to trip it. An alert fires only while the error ratio is strictly greater than its threshold, and that is the > in the generated rule. The detection-time function used < to decide "never", so a ratio exactly at the threshold counted as firing.

This shows up when the threshold is exactly 100%. A 90% SLO over a 50-day period gives the 6-hour page a 10x burn rate, and 10 × 10% = 100%. Even a total outage, an error ratio of 1, never exceeds 1. The CLI printed:

page      10x burn  6h/30m  error ratio > 100%  total outage detected in 6h  UNREACHABLE

Two columns of the same row disagreed. It now reads detected in never. The same happens with an 80% SLO over 25 or 50 days, or 90% over 100 or 300.

The fix is one character (<=). The guard is wider than the bug. A sweep over 10 SLOs and every period from 1 to 366 days checks that each alert shows a finite detection time exactly when it is reachable. It fails on the old code and runs in about 50 ms.

Numbers

SeededCaught beforeCaught after
SLO burn-rate alerts (engine.mjs)12712
HVAC load (load.mjs)12912
Total2416 (67%)24 (100%)

Real defects found: 1, patched: 1.