14:75 is not quarter past three. Red-teaming the service load check

16 faults seeded into the service load check, 11 caught. Three tools read an impossible clock time like 14:75 as a real one; a new CI check now tries them all.

Today's red-team run seeded 16 faults into the service load check, the tool that reads a year of utility interval data and finds the measured peak an electrician needs for NEC 220.87. Eight went into interval.mjs (the CSV and Green Button reader) and eight into greenbutton.mjs (the shared ESPI XML reader). redteam.py campaign applied each one, ran the suite and restored the file.

The XML reader's suite caught all 8. The CSV reader's caught 3 of 8:

FaultWhy it got throughNow
ISO day \d{1,2} to \d{2,2}no test typed 2025-1-5test added
12:xx AM in a separate time column read as 1 AMthe AM test used a combined date-time celltest added
end of the period min * 60000 to min / 60000nothing checked to, span or coverage on clean datatest added
second >= 0 to second > 0cannot change anything: the other timestamp column is never column 0equivalent
block sort comparator brokenrows reach it already sortedequivalent

So 11 of 16 caught before, and every non-equivalent fault caught after.

The bugs a stranger would type

Reading the parser as an attacker turned up two real defects.

A clock time that cannot exist was read as one that does. Date.UTC(2025, 0, 1, 14, 75) is 15:15, not an error, and h * 60 + m does the same for a bare time of day. A Green Button CSV with a corrupted line, 2025-01-01,77:30,77:44,9, put that reading three days after the rest of the file: the tool reported 3.2 days of data with 98.7% of it missing. Hours over 24, minutes over 59 and 24:30 are now refused, and the line is counted as skipped.

One missing line could halve the peak. With no end column, the reader guesses the meter's interval from the median gap between readings. It took the upper median, so a short paste of 15-minute data with one line missing (gaps of 15 and 30 minutes) became "30-minute data": a 4 kW peak was reported as 2 kW, coverage read 120%, and the page warned that hourly-style data understates the peak. A missing reading only ever makes a gap longer, so the lower median is the right one.

Same bug, two more places

The sibling demand-charge interval analyzer already caught 30 February rolling into March, but not minutes: 14:75 became 15:15 there too.

Rather than read every parser by hand, the run added platform/ci/check_clock_rollover.py. It imports each module under ventures/ and platform/ that exports a parse…Time…, parse…Timestamp… or parse…DateTime… function, calls it with 14:75, 2:75 PM, 14:60 and friends, and calls it again with the time each one rolls over to. A parser fails only when both give the same answer, so a video-chapter parser that reads 25:10 as 25 minutes 10 seconds is left alone.

Its first run found a third: the babysitting business kit's medication authorisation form read 8:75pm as 9:15 pm and 13pm as 1 am. The dose spacing check then compared a dose against a time nobody wrote. toMin now refuses those, and keeps 24:00 as the end of a day, which the availability grid uses.

The check takes under a second over 19 modules and runs on every venture pull request through unwired_checks.py, so the next parser that hands raw hours and minutes to Date.UTC fails CI instead of waiting for a red-team run.